2) The sampling frequency of the calculation
conducted between two units varies accord-
ing to the total number of units connected in
the network.
3) As an analog voltage output, the voltage
detected at one unit is output, instead of a
value calculated for the two units.
When GP-XCOM is used, controllers cannot communicate if their software
versions are not compatible. Check the software version while referring to
Section "5.5 Software Version Display Menu" on page 110, and use a
Notice
correct combination.
・Ver. 1.06 or earlier version with Ver. 1.06 r earlier version: Possible
・Ver. 1.06 or earlier version with Ver. 1.10 or later version: Impossible
・Ver. 1.10 or later version with Ver. 1.10 or later version: Possible
5.3.2 Connection of Controller Communication Unit and
Address Setting
1. Mount the controller communication unit (GP-XCOM) to the controller.
For details, refer to section "1.7.2 Mounting the Option Unit" on page 20.
Use the accessory fitting, fix GP-XCOM.
Be sure to turn the power off before starting mounting.
2. Connect GP-XCOM using the link cable for the controller communication
unit (SL-F150/F250/F1000).
3. Turn on the terminator switch of GP-XCOM located at both ends of the
network, and turn off the terminator switch of the other GP-XCOM.
104
Controller communication
unit (GP-XCOM)
Terminator switch OFF
Terminator switch ON
Sampling frequency
No. of connected units
2
200 s approx.
4
400 s approx.
6
600 s approx.
800 s approx.
8
Link cable for controller communi-
cation unit (SL-F150/F250/F1000)
Terminator switch ON