Closed-Loop Control - Siemens SITOP PSU100C 6EP1321-5BA00 Operating Instructions Manual

Table of Contents

Advertisement

Technical data

6.4 Closed-loop control

6.4
Closed-loop control
Dyn. line compensation
(Ue rated ±15%), max.
Dyn. load compensation
(Ia: 10/90/10 %), Ua ± ,typ.
Load step compensation
time
10 to 90 %, typ.
Load step compensation
time
90 to 10 %, typ.
Dyn. line compensation
(Ue rated ±15%), max.
Dyn. load compensation
(Ia: 10/90/10 %), Ua ± ,typ.
Load step compensation
time
10 to 90 %, typ.
Load step compensation
time
90 to 10 %, typ.
36
6EP1321-5BA00
6EP1322-5BA10
(12 V/2 A)
(12 V/6.5 A)
0.1 %
0.1 %
3 %
3 %
4 ms
3 ms
3 ms
3 ms
6EP1332-5BA00
(24 V/2.5 A)
0.1 %
3 %
4 ms
4 ms
6EP1331-5BA00
(24 V/0.6 A)
0.1 %
3 %
3 ms
3 ms
6EP1332-5BA20
(24 V/3.7 A)
0.1 %
3 %
4 ms
4 ms
Operating Instructions, 06.2013, C98130-A7599-A1-2-7629
6EP1331-5BA10
(24 V/1.3 A)
0.1 %
3 %
5 ms
5 ms
6EP1332-5BA10
(24 V/4 A)
0.1 %
3 %
4 ms
4 ms