Rebooting the Device
To reboot the device, type:
admin reboot
Section 3.6
Restoring Factory Defaults
To restore the factory defaults for the device, navigate to admin » restore-factory-defaults and configure the
following parameter(s):
admin restore-factory-defaults
If necessary, include the following options in the command:
Parameter
delete-logs
default-both-partitions
delete-saved-configurations
shutdown
Section 3.7
Decommissioning the Device
Before taking the device out of service, either permanently or for maintenance by a third-party, make sure the
device has been fully decommissioned. This includes removing any sensitive, proprietary information.
To decommission the device, do the following:
1.
Obtain a copy of the RUGGEDCOM ROX II firmware currently installed on the device. For more information,
contact Siemens Customer Support.
2.
Log in to maintenance mode. For more information, refer to
3.
Delete the current boot password/passphrase by typing:
rox-delete-bootpwd --force
Type exit and press Enter.
4.
Rebooting the Device
Description
Synopsis: true or false
Default: false
Delete system logs as well as restoring default settings.
Synopsis: true or false
Default: false
Perform the operation on both partitions.
Synopsis: true or false
Default: false
Delete saved configuration files (works with default-both-partitions option).
Synopsis: true or false
Default: false
Shutdown rather than reboot after restoring factory defaults.