RUGGEDCOM RX1512
Installation Guide
7/2019
RC1057-EN-12
Preface
Introduction
Installing the Device
Device Management
Technical Specifications
Certification
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RX1512

  • Page 1 Preface Introduction Installing the Device RUGGEDCOM RX1512 Device Management Modules Technical Specifications Installation Guide Certification 7/2019 RC1057-EN-12...
  • Page 2: Security Information

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3 RUGGEDCOM RX1512 Installation Guide Industry Sector Tel: +1 905 856 5288 300 Applewood Crescent Fax: +1 905 856 1995 https://www.siemens.com/ruggedcom Concord, Ontario Canada, L4K 5C7...
  • Page 4 RUGGEDCOM RX1512 Installation Guide...
  • Page 5: Table Of Contents

    RUGGEDCOM RX1512   Installation Guide Table of Contents Table of Contents Preface ......................Alerts ..............................vii Related Documents ..........................viii Accessing Documentation ........................viii Training ............................viii Customer Support ..........................viii Chapter 1 Introduction ..................... 1.1  Feature Highlights ........................1 1.2    Description ........................... 2 1.3  Required Tools and Materials ......................
  • Page 6   RUGGEDCOM RX1512 Table of Contents Installation Guide Chapter 4 Modules ......................4.1  Available Modules ........................20 4.2  Installing/Removing Line Modules ....................26 Chapter 5 Technical Specifications .................. 5.1  Power Supply Specifications ......................29 5.2  Failsafe Relay Specifications ......................29 5.3  Operating Environment ....................... 30 5.4  Mechanical Specifications ......................
  • Page 7: Preface

    Installation Guide Preface Preface This guide describes the RUGGEDCOM RX1512. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 8: Related Documents

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 9 Installation Guide Preface Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: • Access Siemens' extensive library of support documentation, including FAQs and manuals • Submit SRs or check on the status of an existing SR •...
  • Page 10: Customer Support

      RUGGEDCOM RX1512 Preface Installation Guide Customer Support...
  • Page 11: Introduction

    The RUGGEDCOM RX1512 is designed to provide a high level of immunity to electromagnetic interference (EMI) and heavy electrical surges typical of the harsh environments found in many industrial applications. An operating temperature range of -40 to 85 °C (-40 to 185 °F) allows the RUGGEDCOM RX1512 to be placed in almost any location.
  • Page 12: Description

    Installation Guide Section 1.2 Description The RUGGEDCOM RX1512 features various ports, controls and indicator LEDs on the front panel for connecting, configuring and troubleshooting the device. Figure 1: RUGGEDCOM RX1512 1. Utility USB Port    2. RS232 Serial Console Port (RJ45)    3. Lamp Test/Alarm Cut-Off (LT/ACO) Button    4. Management Port    5. Compact Flash Card Port   ...
  • Page 13: Required Tools And Materials

    RUGGEDCOM RX1512 Chapter 1 Installation Guide Introduction Section 1.3 Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RX1512: Tools/Materials Purpose AC/DC power cord (16 AWG) For connecting power to the device. Lightning protector For protecting the device from harmful electrical strikes.
  • Page 14: Protection On Twisted-Pair Data Ports

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 15: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 16: General Procedure

    Section 2.3 Mounting the Device The RUGGEDCOM RX1512 is designed for maximum mounting and display flexibility. It can be equipped with connectors that allow it to be installed in a 35 mm (1.4 in) DIN rail, or directly on a panel.
  • Page 17: Mounting The Device On A Din Rail

    Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RX1512 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
  • Page 18: Mounting The Device To A Panel

    Section 2.3.2 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RX1512 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws.
  • Page 19: Connecting Power

    1. Normally Closed    2. Common    3. Normally Open Section 2.5 Connecting Power The RUGGEDCOM RX1512 supports a single low DC power source. DANGER! Electrocution hazard – risk of serious personal injury or death. Make sure the power source is off before servicing the power terminal.
  • Page 20 Damage to the device may occur otherwise. Removing the jumper may also void the warranty. NOTE The RUGGEDCOM RX1512 works with both positive VDC power supplies and negative VDC power supplies. NOTE For information about how to safely test the dielectric strength of the device, refer to Section 2.5.2,...
  • Page 21 RUGGEDCOM RX1512 Chapter 2 Installation Guide Installing the Device Figure 6: DC Terminal Block Wiring for Negative VDC Power Supplies 1. Surge Ground Terminal    2. Positive (+) Terminal    3. Chassis Ground Terminal    4. Negative (-) Terminal    5. Jumper    6. Chassis Ground Connection Connect the positive wire from the power source to the positive (+) terminal on the terminal block.
  • Page 22: Testing Dielectric Strength

    Installation Guide Section 2.5.2 Testing Dielectric Strength Before performing any dielectric strength or HIPOT (High Potential) testing on the RUGGEDCOM RX1512 in the field, do the following: IMPORTANT! In normal operation, the jumper between the chassis ground and surge ground terminals must be installed for proper operation.
  • Page 23: Device Management

    RUGGEDCOM RX1512 Chapter 3 Installation Guide Device Management Device Management This section describes how to connect to and manage the device. CONTENTS • Section 3.1, “Connecting to the Device” • Section 3.2, “Configuring the Device” • Section 3.3, “Accessing the CompactFlash Card” Section 3.1...
  • Page 24: Communication Ports

    For information about how to connect to the device via the management port, refer to either the RUGGEDCOM ROX II Web Interface User Guide or the RUGGEDCOM ROX II CLI User Guide for the RUGGEDCOM RX1512. The management port is a 10/100Base-TX copper Ethernet port with an RJ-45 connector. The following is the pin-...
  • Page 25: Configuring The Device

    RUGGEDCOM ROX II User Guide associated with the installed software release. Section 3.3 Accessing the CompactFlash Card The RUGGEDCOM RX1512 features a removable CompactFlash (CF) card that stores configuration files, firmware (active and backup versions), file-based feature keys and other system files. CAUTION! Configuration hazard –...
  • Page 26: Removing The Cf Card

    Chapter 3 RUGGEDCOM RX1512 Device Management Installation Guide Figure 11: Inserting the CF Card 1. CompactFlash Card    2. Access Panel Secure the CF card access panel to the chassis. Removing the CF card To remove the CF card from the device, do the following: Make sure the device is powered down.
  • Page 27 RUGGEDCOM RX1512 Chapter 3 Installation Guide Device Management Figure 12: Removing the CF Card 1. Ejector Button    2. CompactFlash Card    3. Access Panel Press the ejector button to the left of the CF card and then pull the card out. Secure the CF card access panel to the chassis.
  • Page 28 Chapter 3 RUGGEDCOM RX1512 Device Management Installation Guide Accessing the CompactFlash Card...
  • Page 29: Modules

    Modules Modules The RUGGEDCOM RX1512 features slots for up to two field-replaceable line modules, which can be used to expand and customize the capabilities of the device to suit specific applications. A variety of modules are available, each featuring a specific type of communication port: copper Ethernet, fiber optic Ethernet, SFP, WAN, cellular modem and DDS.
  • Page 30: Available Modules

    Modules Installation Guide Section 4.1 Available Modules The following is a list of all power and line modules available for use in the RUGGEDCOM RX1512. For more RUGGEDCOM RX1500 Series Modules Catalog information about individual modules, refer to the [https:// support.industry.siemens.com/cs/ca/en/view/109747072].
  • Page 31 RUGGEDCOM RX1512 Chapter 4 Installation Guide Modules Distance: 100 m (328 ft) RUGGEDCOM RX1500PN LM 4TX03B Specifications Article Numbers Ports: 4 6GK6015-0AL20-0PF0 (Standard) Speed: 100 Mbps 6GK6015-0AL20-0PF1 (Conformal Coated) Interface: TX Port Type: M12 (8-Pin, A-Coded, Controlled Bypass) Distance: 100 m (328 ft)
  • Page 32: Wan Modules

    Chapter 4 RUGGEDCOM RX1512 Modules Installation Guide RUGGEDCOM RX1500PN LM FG03 Specifications Article Numbers Mode: SM 6GK6015-0AL20-0EC0 (Standard) Speed: 1000 Mbps 6GK6015-0AL20-0EC1 Interface: LX (Conformal Coated) Wavelength: 820 nm Ports: 4 Port Type: LC Distance: 10 km (6.2 mi) RUGGEDCOM RX1500PN LM FG50...
  • Page 33: Cellular Modem Modules

    RUGGEDCOM RX1512 Chapter 4 Installation Guide Modules RUGGEDCOM RX1500PN LM E02 Specifications Article Numbers (Standard) Interface: E1 6GK6015-0AL20-0HC0 (Standard) Ports: 2 6GK6015-0AL20-0HC1 Port Type: BNC (75 Ω) (Conformal Coated) RUGGEDCOM RX1500PN LM D02 Specifications Article Numbers (Standard) Speed: 56 kbps (Master/Slave) or...
  • Page 34 Chapter 4 RUGGEDCOM RX1512 Modules Installation Guide Antennas: 1 x GSM/EDGE/HSPA +, 1 x EVDO Rev A, 2 x Receive Diversity (Secondary) SIM: Dual Mini-SIM (2FF) RUGGEDCOM RX1500PN LM W41 Specifications Article Numbers (Standard) Services: 4G LTE/HSPA+/HSDPA/ 6GK6015-0AL20-0WG0 HSUPA/DC-HSPA+/UMTS/WCDAM/ (Standard)
  • Page 35 RUGGEDCOM RX1512 Chapter 4 Installation Guide Modules Networking: Realtek RTL8111, RJ45 Gigabit Ethernet Interface USB: 2 x USB 2.1 Video: Intel 4108 Graphics Processor, DVI-D RUGGEDCOM RX1500PN LM APE1402W7 Specifications Article Numbers (Standard) Operating System: Windows® 6GK6015-0AL20-0GC0 Embedded Standard 7 (Standard) Processor: Intel Atom E660 1.3...
  • Page 36: Installing/Removing Line Modules

    Chapter 4 RUGGEDCOM RX1512 Modules Installation Guide Networking: Realtek RTL8111, RJ45 Gigabit Ethernet Interface USB: 2 x USB 2.1 Video: Intel 4108 Graphics Processor, DVI-D Maximum combined USB device power consumption is 500 mA at 5 V. Blank Modules RUGGEDCOM RX1500PN PS XXP...
  • Page 37: Removing A Module

    RUGGEDCOM RX1512 Chapter 4 Installation Guide Modules Removing a Module To remove a line module, do the following: [Optional] If the device is installed in a rack, remove it from the rack. Loosen the screws that secure the module. Pull the module from the chassis to disconnect it.
  • Page 38 Chapter 4 RUGGEDCOM RX1512 Modules Installation Guide Figure 15: Installing a Module 1. Module    2. Chassis    3. Screw Tighten the screws to secure the module. [Optional] If necessary, install the device in the rack. Installing/Removing Line Modules...
  • Page 39: Technical Specifications

    RUGGEDCOM RX1512 Chapter 5 Installation Guide Technical Specifications Technical Specifications This section provides important technical specifications related to the device. CONTENTS • Section 5.1, “Power Supply Specifications” • Section 5.2, “Failsafe Relay Specifications” • Section 5.3, “Operating Environment” • Section 5.4, “Mechanical Specifications” •...
  • Page 40: Operating Environment

    Temperature limits for select line modules may differ from that which can be withstood by the RUGGEDCOM RX1512. Make sure the selected modules are rated for the expected environmental conditions before deployment. For more information, refer to the RUGGEDCOM RX1512 Series Modules Catalog.
  • Page 41 RUGGEDCOM RX1512 Chapter 5 Installation Guide Technical Specifications 184.4 122.7 Figure 16: Overall Dimensions 160.5 152.4 150.4 78.2 Figure 17: Panel and Din Rail Mount Dimensions Dimension Drawings...
  • Page 42 Chapter 5 RUGGEDCOM RX1512 Technical Specifications Installation Guide 162.5 151.4 19.7 Figure 18: Line Module Dimensions 162.5 151.8 40.6 Figure 19: Power Module Dimensions Dimension Drawings...
  • Page 43: Certification

    Installation Guide Certification Certification The RUGGEDCOM RX1512 device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. NOTE Certifications related to individual modules are detailed in the RUGGEDCOM Modules Catalog for the device available online.
  • Page 44: European Union (Eu)

    The device is marked with a CE marking and notified body number, and can be used throughout the European community. 0680 A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd. For contact information, refer to “Contacting Siemens” European Union (EU)
  • Page 45: Fcc

    • Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health Section 6.1.5 ISED This device is declared by Siemens Canada Ltd to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) Section 6.1.6...
  • Page 46: Other Approvals

    • IEC 61850-3 Communication Networks and Systems in Substations – Part 3: General Requirements Section 6.2 EMC and Environmental Type Tests The RUGGEDCOM RX1512 has passed the following Electromagnetic Compatibility (EMC) and environmental tests. EMC Type Test for IEC 61850-3 Severity Test...
  • Page 47: Environmental Type Tests

    EMC Immunity Type Tests for IEEE 1613 NOTE The RUGGEDCOM RX1512 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires error-free and interrupted communications.
  • Page 48 Chapter 6 RUGGEDCOM RX1512 Certification Installation Guide Severity Test Description Test Levels Levels IEC 60068-2-2 Dry Heat Test Bd 85 °C (185 °F), 16 Hours IEC 60068-2-30 Humidity (Damp Heat, Cyclic) Test Db 95% (non-condensing), 55 °C (131 °F), 6 cycles...