Siemens RUGGEDCOM RX1501 Installation Manual
Siemens RUGGEDCOM RX1501 Installation Manual

Siemens RUGGEDCOM RX1501 Installation Manual

Hide thumbs Also See for RUGGEDCOM RX1501:

Advertisement

Quick Links

RUGGEDCOM RX1501
Installation Guide
5/2019
RC1054-EN-11
Preface
Introduction
Installing the Device
Device Management
Modules
Technical Specifications
Certification
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RX1501

  • Page 1 Preface Introduction Installing the Device RUGGEDCOM RX1501 Device Management Modules Technical Specifications Installation Guide Certification 5/2019 RC1054-EN-11...
  • Page 2 Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3 RUGGEDCOM RX1501 Installation Guide Industry Sector Tel: +1 905 856 5288 300 Applewood Crescent Fax: +1 905 856 1995 https://www.siemens.com/ruggedcom Concord, Ontario Canada, L4K 5C7...
  • Page 4 RUGGEDCOM RX1501 Installation Guide...
  • Page 5: Table Of Contents

    RUGGEDCOM RX1501   Installation Guide Table of Contents Table of Contents Preface ......................Alerts ..............................vii Related Documents ..........................viii Accessing Documentation ........................viii Training ............................viii Customer Support ..........................viii Chapter 1 Introduction ..................... 1.1  Feature Highlights ........................1 1.2    Description ........................... 2 1.3  Required Tools and Materials ......................
  • Page 6   RUGGEDCOM RX1501 Table of Contents Installation Guide Chapter 4 Modules ......................4.1  Available Modules ........................26 4.2  Installing/Removing Line Modules ....................34 4.3  Installing/Removing Power Modules ..................... 36 Chapter 5 Technical Specifications .................. 5.1  Power Supply Specifications ......................39 5.2  Failsafe Relay Specifications ......................40 5.3  Operating Environment .......................
  • Page 7: Preface

    Installation Guide Preface Preface This guide describes the RUGGEDCOM RX1501. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 8: Related Documents

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 9 Installation Guide Preface Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: • Access Siemens' extensive library of support documentation, including FAQs and manuals • Submit SRs or check on the status of an existing SR •...
  • Page 10: Customer Support

      RUGGEDCOM RX1501 Preface Installation Guide Customer Support...
  • Page 11: Introduction

    The RUGGEDCOM RX1501 is designed to provide a high level of immunity to electromagnetic interference (EMI) and heavy electrical surges typical of the harsh environments found in many industrial applications. An operating temperature range of -40 to 85 °C (-40 to 185 °F) allows the RUGGEDCOM RX1501 to be placed in almost any location.
  • Page 12: Description

    Installation Guide Section 1.2 Description The RUGGEDCOM RX1501 features various ports, controls and indicator LEDs on the front panel for connecting, configuring and troubleshooting the device. Figure 1: RUGGEDCOM RX1501 1. Management Port    2. RS232 Serial Console Port (DB9)    3. Utility USB Port    4. Port Status LEDs    5. Power Status LEDs    6. Alarm Indicator LED   ...
  • Page 13: Required Tools And Materials

    RUGGEDCOM RX1501 Chapter 1 Installation Guide Introduction Section 1.3 Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RX1501: Tools/Materials Purpose AC/DC power cord (16 AWG) For connecting power to the device. Lightning protector For protecting the device from harmful electrical strikes.
  • Page 14: Protection On Twisted-Pair Data Ports

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 15: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 16: General Procedure

    Mounting the Device The RUGGEDCOM RX1501 is designed for maximum mounting and display flexibility. It can be equipped with connectors that allow it to be installed in a 48 cm (19 in) rack, 35 mm (1.4 in) DIN rail or directly on a panel.
  • Page 17: Mounting The Device To A Rack

    Section 2.3.3, “Mounting the Device to a Panel” Section 2.3.1 Mounting the Device to a Rack For rack mount installations, the RUGGEDCOM RX1501 can be equipped with rack mount adapters pre-installed at the front or rear of the chassis. Additional adapters are provided for added stability. CAUTION! Vibration hazard –...
  • Page 18: Mounting The Device On A Din Rail

    Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RX1501 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
  • Page 19: Mounting The Device To A Panel

    Section 2.3.3 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RX1501 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws.
  • Page 20: Connecting The Failsafe Alarm Relay

    Control of the failsafe relay output is configurable through ROX II. One common application for this relay is to signal an alarm if a power failure occurs. For more information, refer to the ROX II User Guide for the RUGGEDCOM RX1501. The following shows the proper relay connections.
  • Page 21: Connecting Power

    Section 2.5 Connecting Power The RUGGEDCOM RX1501 supports a single high AC, high DC or low DC power module. Power modules can be equipped with either a screw or European-style (Euroblock) terminal block. The screw terminal block is installed using Phillips screws and compression plates, allowing either bare wire connections or crimped terminal lugs.
  • Page 22: Connecting High Ac/Dc Power

    Chapter 2 RUGGEDCOM RX1501 Installing the Device Installation Guide Section 2.5.1 Connecting High AC/DC Power To connect a high AC/DC power supply to the device, do the following: DANGER! Electrocution hazard – risk of death, serious personal injury and/or damage to the device. Make sure the supplied cover is always installed over high voltage screw terminal blocks.
  • Page 23 RUGGEDCOM RX1501 Chapter 2 Installation Guide Installing the Device Figure 7: AC Terminal Block Wiring – Screw Terminal Block for HI Power Supplies 1. Not Connected    2. Removable Screw Terminal Block    3. Non-removable Screw Terminal Block    4. Positive/Live (+/L) Terminal    5. Ground Terminal    6. Negative/Neutral (-/N) Terminal Connect the positive wire from the power source to the positive/live (+/L) terminal on the terminal block.
  • Page 24 Installation Guide Figure 8: Assembling the Safety Cover 1. Screw    2. Safety Cover    3. Screw Terminal Block    4. RUGGEDCOM RX1501 Device Using a braided wire or other appropriate grounding wire, connect the ground terminal to the chassis ground connection. The ground terminal is used as the ground conductor for surge and transient suppression circuitry internal to the unit.
  • Page 25: Connecting Low Dc Power

    Electrical hazard – risk of damage to equipment. Do not connect AC power cables to a 12, 24 or 48 VDC power supply terminal block. Damage to the power supply may occur. NOTE The RUGGEDCOM RX1501 works with both positive VDC power supplies and negative VDC power supplies. NOTE The screw terminal block is installed using Phillips screws and compression plates, allowing either bare wire connections or crimped terminal lugs.
  • Page 26 Chapter 2 RUGGEDCOM RX1501 Installing the Device Installation Guide Figure 10: DC Terminal Block Wiring – European-style (Euroblock) Terminal Block for 12P, 24P and 48P Power Supplies 1. European-style (Euroblock) Terminal Block    2. Positive (+) Terminal    3. Negative (-) Terminal    4. Ground Terminal Figure 11: DC Terminal Block Wiring – Screw Terminal Block for 12P, 24P and 48P Power Supplies 1. Not Connected   ...
  • Page 27 RUGGEDCOM RX1501 Chapter 2 Installation Guide Installing the Device Figure 12: DC Terminal Block Wiring – European-style (Euroblock) Terminal Block for -12P, -24P and -48P Power Supplies 1. Not Connected    2. European-style (Euroblock) Terminal Block    3. Positive (+) Terminal    4. Negative (-) Terminal    5. Ground Terminal Figure 13: DC Terminal Block Wiring – Screw Terminal Block for -12P, -24P and -48P Power Supplies 1. Not Connected   ...
  • Page 28 Installation Guide Figure 14: Assembling the Safety Cover 1. Screw    2. Safety Cover    3. Screw Terminal Block    4. RUGGEDCOM RX1501 Device Using a braided wire or other appropriate grounding wire, connect the ground terminal to the chassis ground connection. The surge ground terminal is used as the ground conductor for all surge and transient suppression circuitry internal to the unit.
  • Page 29 RUGGEDCOM RX1501 Chapter 2 Installation Guide Installing the Device Figure 15: Chassis Ground Connection 1. #10-32 Screw    2. #10 Ring Lug Install the safety cover over the terminal block. This is mandatory for 48 VDC or -48 VDC power supplies. Connecting Low DC Power...
  • Page 30 Chapter 2 RUGGEDCOM RX1501 Installing the Device Installation Guide Connecting Low DC Power...
  • Page 31: Device Management

    RUGGEDCOM RX1501 Chapter 3 Installation Guide Device Management Device Management This section describes how to connect to and manage the device. CONTENTS • Section 3.1, “Connecting to the Device” • Section 3.2, “Configuring the Device” • Section 3.3, “Accessing the CompactFlash Card” Section 3.1...
  • Page 32: Configuring The Device

    For information about how to connect to the device via the management port, refer to either the RUGGEDCOM ROX II Web Interface User Guide or the RUGGEDCOM ROX II CLI User Guide for the RUGGEDCOM RX1501. The management port is a 10/100Base-TX copper Ethernet port with an RJ-45 connector. The following is the pin-...
  • Page 33: Accessing The Compactflash Card

    Device Management Section 3.3 Accessing the CompactFlash Card The RUGGEDCOM RX1501 features a removable CompactFlash (CF) card that stores configuration files, firmware (active and backup versions), file-based feature keys and other system files. CAUTION! Configuration hazard – risk of data corruption/loss. Do not remove or insert the CF card when the device is powered on.
  • Page 34 Chapter 3 RUGGEDCOM RX1501 Device Management Installation Guide Figure 18: Inserting the CF Card 1. CompactFlash Card    2. Access Panel Secure the CF card access panel to the chassis. Removing the CF card To remove the CF card from the device, do the following: Make sure the device is powered down.
  • Page 35: Modules

    Modules Modules The RUGGEDCOM RX1501 features slots for up to four field-replaceable line modules, which can be used to expand and customize the capabilities of the device to suit specific applications. A variety of modules are available, each featuring a specific type of communication port: copper Ethernet, fiber optic Ethernet, SFP, WAN, cellular modem and DDS.
  • Page 36: Available Modules

    Modules Installation Guide Section 4.1 Available Modules The following is a list of all power and line modules available for use in the RUGGEDCOM RX1501. For more RUGGEDCOM RX1500 Series Modules Catalog information about individual modules, refer to the [https:// support.industry.siemens.com/cs/ca/en/view/109747072].
  • Page 37 RUGGEDCOM RX1501 Chapter 4 Installation Guide Modules RUGGEDCOM RX1500PN PS 48 Specifications Article Numbers Input Range: 36 to 72 VDC 6GK6015-0AL12-0AA0 (Standard) Terminal Type: Removable Screw 6GK6015-0AL12-0AA1 (Conformal Coated) RUGGEDCOM RX1500PN PS 48P Specifications Article Numbers Input Range: 36 to 72 VDC...
  • Page 38 Chapter 4 RUGGEDCOM RX1501 Modules Installation Guide RUGGEDCOM RX1500PN LM CG03B Specifications Article Numbers Ports: 2 6GK6015-0AL20-0PE0 (Standard) Speed: 1000 Mbps 6GK6015-0AL20-0PE1 (Conformal Coated) Interface: TX Port Type: M12 (8-Pin, A-Coded, Controlled Bypass) Distance: 100 m (328 ft) RUGGEDCOM RX1500PN LM X CG04...
  • Page 39 RUGGEDCOM RX1501 Chapter 4 Installation Guide Modules RUGGEDCOM RX1500PN LM 6TX01 Specifications Article Numbers Ports: 6 6GK6015-0AL20-0NB0 (Standard) Speed: 100 Mbps 6GK6015-0AL20-0NB1 Interface: TX (Conformal Coated) Port Type: RJ45 Distance: 100 m (328 ft) Fiber Optic Ethernet Modules RUGGEDCOM RX1500PN LM 4FX11...
  • Page 40 Chapter 4 RUGGEDCOM RX1501 Modules Installation Guide RUGGEDCOM RX1500PN LM 6FX50 Specifications Article Numbers SFP Sockets: 6 6GK6015-0AL20-0JD0 (Standard) Speed: 100 Mbps 6GK6015-0AL20-0JD1 (Conformal Coated) WAN Modules RUGGEDCOM RX1500PN LM S01 Specifications Article Numbers (Standard) Standard: RS232/RS422/RS485 6GK6015-0AL20-0KB0 (Standard) Ports: 6...
  • Page 41 RUGGEDCOM RX1501 Chapter 4 Installation Guide Modules SIM: Dual Mini-SIM (2FF) RUGGEDCOM RX1500PN LM W12 Specifications Article Numbers (Standard) Services: GSM/EDGE/HSPA+ 6GK6015-0AL20-0WC0 (Standard) Region: North America (AT&T), European Union, Australia 6GK6015-0AL20-0WC1 (Conformal Coated) Port Type: 50 Ω SMA Antennas: 2 x GSM/EDGE/HSPA+,...
  • Page 42 Chapter 4 RUGGEDCOM RX1501 Modules Installation Guide SIM: Dual Mini-SIM (2FF) RUGGEDCOM RX1500PN LM W61 Specifications Article Numbers (Standard) Services: 4G LTE/HSPA+/CDMA/ 6GK6015-0AL20-0WJ0 EVDO/GPS/GNSS (Standard) Region: North America (Verizon, 6GK6015-0AL20-0WJ1 Sprint) (Conformal Coated) Port Type: 50 Ω SMA Antennas: 1 x LTE Main, 1 x LTE...
  • Page 43 RUGGEDCOM RX1501 Chapter 4 Installation Guide Modules RUGGEDCOM RX1500PN LM APE1404 Specifications Article Numbers (Standard) Operating System: Debian Linux® 6GK6015-0AL20-0GD0 (Standard) Processor: Intel Atom E660T 1.3 GHz, 512 KB L2 Cache 6GK6015-0AL20-0GD1 (Conformal Coated) RAM: 2 GB DDR2, 800 MHz, 32-...
  • Page 44: Installing/Removing Line Modules

    Chapter 4 RUGGEDCOM RX1501 Modules Installation Guide RUGGEDCOM RX1500PN LM Blank Specifications Article Numbers — 6GK6015-0AL20-0AA0 (Standard) 6GK6015-0AL20-0AA1 (Conformal Coated) Section 4.2 Installing/Removing Line Modules Upon installing a new line module in the device, all features associated with the module are available in RUGGEDCOM ROX II.
  • Page 45 RUGGEDCOM RX1501 Chapter 4 Installation Guide Modules Figure 21: Removing a Module 1. Module    2. Chassis    3. Screw Install a new module or a blank module (to prevent the ingress of dust and dirt). [Optional] If necessary, install the device in the rack. Installing a Module To install a line module, do the following: [Optional] If the device is installed in a rack, remove it from the rack.
  • Page 46: Installing/Removing Power Modules

    RUGGEDCOM RX1501 Modules Installation Guide Section 4.3 Installing/Removing Power Modules The RUGGEDCOM RX1501 supports a single power module. Figure 23:  Power Module 1. Power Module CAUTION! Contamination hazard – risk of equipment damage. Prevent the ingress of water, dirts and other debris that may lead to premature equipment failure. Always make sure slots are not left empty.
  • Page 47 RUGGEDCOM RX1501 Chapter 4 Installation Guide Modules Disconnect the power supply wiring from the terminal block. Alternatively, for convenience, remove the terminal block with the wiring still connected and set it aside to be connected later to the new module.
  • Page 48 Chapter 4 RUGGEDCOM RX1501 Modules Installation Guide Installing/Removing Power Modules...
  • Page 49: Technical Specifications

    RUGGEDCOM RX1501 Chapter 5 Installation Guide Technical Specifications Technical Specifications This section provides important technical specifications related to the device. CONTENTS • Section 5.1, “Power Supply Specifications” • Section 5.2, “Failsafe Relay Specifications” • Section 5.3, “Operating Environment” • Section 5.4, “Mechanical Specifications” •...
  • Page 50: Failsafe Relay Specifications

    Temperature limits for select line modules may differ from that which can be withstood by the RUGGEDCOM RX1501. Make sure the selected modules are rated for the expected environmental conditions before deployment. For more information, refer to the RUGGEDCOM RX1501 Series Modules Catalog.
  • Page 51: Dimension Drawings

    RUGGEDCOM RX1501 Chapter 5 Installation Guide Technical Specifications Section 5.5 Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. 440.9 Figure 26: Overall Dimensions Dimension Drawings...
  • Page 52 Chapter 5 RUGGEDCOM RX1501 Technical Specifications Installation Guide 11.7 463.8 21.1 Figure 27: Rack Mount Dimensions 479.0 11.7 21.1 489.2 Figure 28: Panel and Din Rail Mount Dimensions Dimension Drawings...
  • Page 53 RUGGEDCOM RX1501 Chapter 5 Installation Guide Technical Specifications 162.5 151.4 19.7 Figure 29: Line Module Dimensions 162.5 151.8 40.6 Figure 30: Power Module Dimensions Dimension Drawings...
  • Page 54 Chapter 5 RUGGEDCOM RX1501 Technical Specifications Installation Guide Dimension Drawings...
  • Page 55: Certification

    Installation Guide Certification Certification The RUGGEDCOM RX1501 device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. NOTE Certifications related to individual modules are detailed in the RUGGEDCOM Modules Catalog for the device available online.
  • Page 56: Tüv Süd

    Information Technology Equipment – Safety – Part 1: General Requirements) Section 6.1.3 European Union (EU) This device is declared by Siemens Canada Ltd to comply with essential requirements and other relevant provisions of the following EU directives: • Directive 2014/30/EU Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility (recast) Text with EEA relevance •...
  • Page 57: Fcc

    The device is marked with a CE marking and notified body number, and can be used throughout the European community. 0680 A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd. For contact information, refer to “Contacting Siemens”.
  • Page 58: Acma

    Section 6.1.8 RoHS This device is declared by Siemens Canada Ltd to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: • China RoHS 2...
  • Page 59: Emc And Environmental Type Tests

    RUGGEDCOM RX1501 Chapter 6 Installation Guide Certification Section 6.2 EMC and Environmental Type Tests The RUGGEDCOM RX1501 has passed the following Electromagnetic Compatibility (EMC) and environmental tests. EMC Type Test for IEC 61850-3 Severity Test Description Test Levels Levels IEC 61000-4-2 Enclosure Contact ±...
  • Page 60 EMC Immunity Type Tests for IEEE 1613 NOTE The RUGGEDCOM RX1501 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires error-free and interrupted communications.
  • Page 61 RUGGEDCOM RX1501 Chapter 6 Installation Guide Certification Environmental Type Tests Severity Test Description Test Levels Levels IEC 60068-2-1 Cold Temperature Test Ad -40 °C (-40 °F), 16 Hours IEC 60068-2-2 Dry Heat Test Bd 85 °C (185 °F), 16 Hours...
  • Page 62 Chapter 6 RUGGEDCOM RX1501 Certification Installation Guide EMC and Environmental Type Tests...

Table of Contents