UM8000
S
S
5
ETTING
ECTION
Subscribers can listen to a message as it is being recorded in their mailbox by using
the live monitor feature. To monitor messages using a phone, the phone system and
the subscriber's extension must be configured properly. Use the phone system
programming interface (either a CAT phone or a SV8300 PCPro) to enter the phone
system programming commands.
5.1
5.2
Installation Manual
U
L
M
P
IVE
ONITOR

Enable Live Monitor on the Phone System

Enable live monitor for the service restriction class.
Command Code:
First Data:
Second Data:

Configuring Live Monitor on a Subscriber's Extension

Do this procedure for each subscriber extension that will use live monitor.
1.
Set the live monitor mode for the subscriber's extension.
Command Code:
First Data:
Second Data:
2.
Enable live monitor pickup.
Command Code:
First Data:
Second Data:
15186
xxx
Where <xxx> is the service restriction class.
0
Where 0 enables live monitor and
1 disables live monitor systemwide.
1226
xxx
Where <xxx> is the subscriber's
extension number.
0
Where 0 = automatic mode,
1 = manual mode and
3 = off.
1227
xxx
Where <xxx> is the subscriber's
extension number.
3
Issue No. 1.0