Installation Hardware and Tools

The following installation accessories are included in the shipping package (see
One bracket for the MicrOS 410
Two 8mm x 16mm screws
Two 8mm lock washers
Two 8mm plain washers
Two 8mm nuts
Two 8mm x 12mm screws
One pole mounting bracket
Two hose clamps, 2" to 5" application
Four anchor screws (for wall-mount applications)
Four plastic anchors (for wall-mount applications)
You must supply the following tools:
Level
5/16-inch nut driver
1/4-inch flat blade screwdriver
RJ-45 crimping tool
Tower mounting only: stainless or galvanized steel pipe and 1/2-inch or
5/8-inch nuts, bolts, and washers to connect to the tower arm.
Wood pole mounting only: one 1/4-inch diameter, 3 1/2-inch long lag bolt

Site Planning

To ensure safe and durable wiring, installation must follow appropriate electrical and building
codes. Follow the National Electrical Code (NEC) requirements, unless local codes in your area
take precedence over the NEC code.
The following distance limits apply to installations that have 10/100 Base-T Category 5 network
cables attached to the MicrOS 410:
300 feet maximum between devices for 100BaseT operation
500 feet maximum for 10BaseT operation.
The Ethernet duplex and speed setting is configurable.
Note
National Electrical Codes (NEC) Article 800 requires the use of Agency Listed (UL/CSA/TUV) Building
Entrance Protector for all power and data communications cables entering a building. The NEC intends by
Article 800 to protect the building and occupants from fires caused by transient voltage and current surges.