  • Page 1 MicrOS 410 Installation Guide ABB Inc. 3055 Orchard Drive San Jose CA 95134 www.abb.com/tropos 408-331-6800 Part No. 200635-00 Rel A0 2016_06_09...
  • Page 2 Consult the dealer or an experienced radio/TV technician. This Part 15 radio device operates on a non-interference basis with other devices operating at this frequency. Any changes or modification to said product not expressly approved by ABB could void the user's authority to operate this device.
  • Page 3 For EU member countries, this symbol means: Do not dispose of this equipment as unsorted municipal waste. This equipment must be collected separately. The return and collection of this product has not been defined at this time, please contact ABB for return and/or collection.
  • Page 4 MicrOS 410 Installation Guide...
  • Page 5 être effectuées uniquement par du personnel qualifié. The MicrOS 410s are installed in wet, outdoor locations. Make sure closure caps are installed and all cable connections are securely fastened and waterproofed. Surfaces may become hot. Use caution when accessing the MicrOS 410s. MicrOS 410 Installation Guide...
  • Page 6: Table Of Contents

    2 Installing the MicrOS 410 ........
  • Page 7 Figure 7 MicrOS 410 Antenna Patterns ......33 MicrOS 410 Installation Guide...
  • Page 8: Micros 410 Installation Guide

    Table 1 MicrOS 410 Models ........
  • Page 9: Introduction

    Introduction The MicrOS 410 is a single-radio, Wi-Fi Bridge that is designed to connect serial or Ethernet clients such as RTUs or PLCs to an ABB TropOS Wi-Fi mesh network. The MicrOS 410 is designed for general purpose outdoor applications. It functions as a high- power client radio.
  • Page 10: Installing The Micros 410

    Installing the MicrOS 410 This guide explains how to install the MicrOS 410 safely and is intended for trained technical professionals. This chapter covers the following topics: “Product Summary” on page 12 “Preparing for Installation” on page 12 “Mounting Strategies”...
  • Page 11: Product Summary

    MicrOS 410 Bridge, two Ethernet ports (ETSI) Preparing for Installation The MicrOS 410 must be installed by a trained professional, value added reseller, or systems integrator who is familiar with RF planning issues and regulatory limits defined by the governing body of the country in which the unit will be installed. This section explains how to prepare the installation site.
  • Page 12: Figure 1 Micros 410 Exploded View - Rear

    Chapter 2 MicrOS 410 Exploded View - Rear Figure 1 Exploded View Callouts Table 2 Item Description MicrOS 410 Unit Mounting bracket M8 x 16mm screw (2 pieces) M8 split washer (2 pieces) M8 flat washer (2 pieces) M8 nut (2 pieces)
  • Page 13: Installation Hardware And Tools

    Chapter 2 Installation Hardware and Tools The following installation accessories are included in the shipping package (see Figure One bracket for the MicrOS 410 Two 8mm x 16mm screws Two 8mm lock washers Two 8mm plain washers Two 8mm nuts...
  • Page 14: Location Guidelines

    Building materials—Radio penetration is influenced by the building material used in construction. For example, drywall construction permits greater range than concrete blocks. Safety Installing the MicrOS 410 can pose a serious hazard. Be sure to take precautions to avoid the following: Exposure to high voltage lines during installation...
  • Page 15: Mounting Strategies

    21 to determine the best strategy for the selected location. Note To eliminate potential interference from the mounting structure, the MicrOS 410 should be mounted with at least 4 feet of clearance around the antenna radome. MicrOS 410 Installation Guide...
  • Page 16: Pole And Wall Mounting Instructions

    Pole and Wall Mounting Instructions This section explains how to mount the MicrOS 410 on a pole or wall. It is best to mount the unit to aluminum or galvanized steel structures. The mounting brackets are designed to pierce any oxidation layers that are on the outside of the pole, thereby assuring good quality connection to the grounded structure.
  • Page 17: Figure 2 Metal Pole Mounting

    MicrOS 410 Unit Mounting bracket M8 x 16mm screw (2 pieces) M8 split washer (2 pieces) M8 flat washer (2 pieces) M8 nut (2 pieces) M8 x 12mm screw (2pieces) Mounting bracket Hose clamp, 5” (2 pieces) MicrOS 410 Installation Guide...
  • Page 18 Chapter 2 Mount the MicrOS 410 on a metal pole Select a mounting location. You can attach the MicrOS 410 to any pipe or pole with diameter between 2 inches and 5 inches. Slip the flat portion of the clamp under the inner slot of the pole bracket.
  • Page 19: Wood Pole And Wall Mounting

    Wall Mount the MicrOS 410 on a wood pole or wall Select a mounting location. You can attach the MicrOS 410 to any outdoor wood pole of diameter at least 1 inch. Attach the pole bracket to the pole by threading a 1/4-inch lag bolt through the hole in the clamp slot to the pole.
  • Page 20: Connecting Power And Data Cables

    Depending on the specific application, the use of one or both connectors may be required. If you have a MicrOS 410 equipped with two Ethernet ports, either or both ports can be used for Ethernet clients. Power must be applied on port 1.
  • Page 21 Wired Client Scenario Recommended wiring One RS-232 serial client • Connect the wired client to Port 2 (serial) on the MicrOS 410 • Provide power to the MicrOS 410 on Port 1 Two RS-232 serial clients • Connect the RS-232 serial clients to Port 2 (serial) on the MicrOS •...
  • Page 22: Figure 5 Routing The Data/Power Cable To The Router

    Connecting the Ethernet cable Have the Ethernet data cable, nut, rubber boots, and cable gland available. Remove the cable gland from the bottom of the MicrOS 410. For power and Ethernet connectivity, use Port 1. Press the tab on the RJ45 connector down as you push the cable through the nut. Make sure...
  • Page 23: Led Status Indicator

    Table 7 (pin 1=TX, pin 3=RX), the Configuration Utility for the serial port should be set up for port 2 (for more information, see the MicrOS 410 User Guide). LED Status Indicator The MicrOS 410 is equipped with LED status indicator. The LED indicator has three states, as...
  • Page 24: Alignment Led

    The unit is associated with the network and operating properly. Alignment LED The MicrOS 410 has an alignment LED on the back of the unit. This LED helps the installer optimally aim the MicrOS 410 at the Wi-Fi router to which it will communicate. The MicrOS...
  • Page 25: Safety And Servicing Information

    LED will flash faster as signal strength increases and slower as signal strength decreases. Rotate the MicrOS 410 on the pole until the alignment LED is blinking as fast as possible. The alignment LED will stop blinking after 15 minutes. If the alignment LED is needed after 15 minutes, turn it on using the configuration interface for the unit, or power the unit off and on again.
  • Page 26: Safety Guidelines

    — The use of wireless devices in hospitals is restricted to the limits set forth by each hospital. Servicing the MicrOS 410 The MicrOS 410 has no user serviceable parts inside. For any service-related issues, contact Customer Support (tropos.support@nam.abb.com). MicrOS 410 Installation Guide...
  • Page 27: Product Specifications

    Product Specifications The tables in this chapter contain specifications for the MicrOS 410: “Physical Specifications” on page 28 “Interfaces” on page 30 “Protection/Power” on page 30 “Certifications, Other” on page 31 Physical Specifications Table 10 Specification Value Physical Dimensions (without mounting brackets) Inches Height: 9.85"...
  • Page 28 Table 10 Specification Value Color Color Gray Shock and Vibration Operational: ETSI 300-19-2-4 Specification T41.E, class 4M3 Transportation: ISTA 2A Status Lamp LED Indicator Off: No power Flashing: Power on, system not ready On: System ready MicrOS 410 Installation Guide...
  • Page 29: Table 11 Interfaces

    EN61000-4-2 Level 4 ESD Immunity EN61000-4-5 Level 4 Surge Immunity Data Port Protection EN61000-4-2 Level 4 ESD Immunity EN61000-4-5 Level 4 Surge Immunity Power Power Input Power input: PoE (7-36 VDC) Power Consumption 3 W typical MicrOS 410 Installation Guide...
  • Page 30: Table 13 Certifications, Other

    Chapter 3 Certifications, Other Table 13 Regulatory Domain Specification U.S. CFR 47 FCC Part 90 CFR 47 FCC Part 15.C; Class B UL579/IEC 60529 IP67 Rated for Outdoor Use ISTA 2A Canada Industry Canada RSS210 MicrOS 410 Installation Guide...
  • Page 31: Antenna Information

    Antenna Information This chapter provides information on the MicrOS 410 antennas. Antenna Specifications Table 14 Specification Description Frequency range 2400 – 2500MHz Gain 13dBi VSWR 2:1 Max Polarization Linear ± 45 Horizontal beam width (3dB); 35 (6dB) Vertical beam width (3dB);...
  • Page 32: Figure 7 Micros 410 Antenna Patterns

    Chapter 4 MicrOS 410 Antenna Patterns Figure 7 MicrOS 410 Installation Guide...
  • Page 33: Wind Loading Considerations

    1 square foot. Pole manufacturers have advised ABB that small communications devices do not present any significant static or dynamic load to these structures.