1) Break the safety circuit before this unit when Eva is in position next to Adam. The LED should blink between
green and red and the safety monitor goes into safe state. For information on indications, see section
Troubleshooting and section LED indication.
2) Reset the safety circuit and safety monitor.
3) Magne should shine green (solid light).
4) Move Eva away from position next to Adam. The LED should change color (solid light) from green to red
and the safety monitor should go to safe state.
5) Move Eva back close to Adam and reset the safety circuit and safety monitor.
Another function test that can be done is to slowly move Eva away from Adam (i.e. slowly open the door from the
fully closed position). The LED should rapidly alternate between green and red when Eva is within 2 mm of the
maximum sensory range of Adam.

Replacing Eva

When a coded Eva needs to be replaced, the old code must be deleted from the internal Adam sensor in Magne.
To delete a coded Eva, follow the instructions below for Eden Dynamic and OSSD. (This is not necessary when
replacing an Eva General with another Eva General.)
Eden Dynamic
1) Move the old Eva out of sensory range.
2) Disconnect the power supply voltage to Magne. (0 V should be connected at all times.)
3) Connect +24 VDC to Dynamic in.
4) Connect power voltage to Magne (marked +24 VDC).
5) Disconnect the voltage to Dynamic in after 5 seconds but within 10 seconds.
The Adam unit in Magne is now reset and Magne should blink red.
6) Disconnect power voltage to Magne (marked +24 VDC).
7) Check that the new Eva is within sensory range and connect the power voltage to Magne.
The LED in Magne should show green and the programming is completed.
Eden OSSD
1) Move the old Eva out of sensory range.
2) Disconnect the power supply voltage to Magne. (0 V should be connected at all times.)
3) Connect +24 VDC to OSSD1 Out and OSSD2 Out.
4) Connect power voltage to Magne (marked +24 VDC).
5) Disconnect the voltage to Dynamic in after 5 seconds but within 10 seconds.
The Adam unit in Magne is now reset and Magne should blink red.
6) Disconnect power voltage to Magne (marked +24 VDC).
7) Check that the new Eva is within sensory range and connect the power voltage to Magne.
The LED in Magne should show green and the programming is completed.