Capacity Specifications - Huawei Airbridge BTS3606A Technical Manual

Cdma base station
Hide thumbs Also See for Airbridge BTS3606A:
Table of Contents

Advertisement

Technical Manual
Airbridge BTS3606A CDMA Base Station
Cabinet dimensions
Power supply
Cabinet weight
Power
consumption
(in full
configuration)
Operating
ambient
temperature
Relative humidity

7.2 Capacity Specifications

The maximum capacity of one BTS3606A is six sector carriers. With the multi-carrier
modules, the capacity can reach 18 sector carriers.
1700 mm x 1200 mm x 1000 mm (Height × Width×Depth)
220/230/240V AC:
Single-phase/three-phase input
Voltage range: 176 V to 264 V
Frequency range: 47 Hz to 63 Hz
Over-voltage protection when the voltage reaches 290V.
110/115/127V AC:
Single-phase/three-phase input
Voltage range: 90 V to 135 V
Frequency range: 47 Hz to 63 Hz
Under-voltage protection when the voltage reaches 85V.
650 kg (excluding the batteries and the built - in transmission
equipment)
6100 W (with air conditioner set to cooling function, and without battery
cabinet)
Air
11000 W (with air conditioner set to cooling function, and with battery
conditioner 
cabinet)
6000 W (with air conditioner set to heating function, and without battery
recharging considered)
4500W (without battery cabinet)
Heat
9500W (with battery cabinet)
exchanger
6000W (heating, without recharging)  
Air
-40°C to 55°C
conditioner 
Heat
-40°C to 45°C
exchanger
5% to 100%
Noise
≤ 65 dBA (The noise varies with the ambient temperature)
Availability ≥ 99.999%
MTBF:≥ 100000 hours
Reliability
MTTR: ≤ 1 hour (excluding the time spent on the journey)
MTTR: ≤3 hours (including the time spent on the journey)
Chapter 7 Technical Specifications
7-2
System Description

Advertisement

Table of Contents
loading