Special
Installation
Requirements

Special Installation Requirements

This security system can be used as an intrusion alarm system, a fire alarm system, and an emer-
gency notification system. Some installations may require configurations dictated by city/state
codes, insurance, or Underwriter's Laboratories (UL). This section describes the various compo-
nent and configuration listings.

UL Listed Systems

This section describes the requirements for UL Listed systems.

Basic System

Control Panel (60-874-95R).
Standard Class II 8.0 VAC, 300 mA Power Transformer; manufacturer—Sino America,
(A1014444-0) Part No. 22-117.
Dialog™ Telephone Interface Module (DTIM) (60-879-95R).
Backup Battery 4.8 VDC rechargeable NiCd battery pack (34-057).
A 2 k Ohm EOL Resistor (49-467) is required for UL Listed systems.

Household Burglary Alarm System Unit (UL 1023)

Basic system, plus:
Hardwire Magnetic Contact (13-068 or 13-071) or Wireless Learn Mode Door/Window Sen-
sor (60-362), Wireless Learn Mode PIR Motion Sensor (60-703-95 or 60-639).
RECEIVER TROUBLE set to on.
EXIT DELAY set to 60 seconds or less.
QUICK EXIT set to off.
SIREN TIMEOUT set to 4 minutes or more.
ENTRY DELAY set to 45 seconds or less.
QUIET TIME set to off.

Household Fire Warning System (UL 985)

Basic system, plus:
Wireless Smoke Sensor (60-506-319.5 or 60-848-95) learned into sensor group 26.
RECEIVER TROUBLE set to on.
QUIET TIME set to off.
EXIT EXTENSION set to off.
SIREN TIMEOUT set to 4 minutes or more.

Digital Alarm Communicator System (UL 1635)

Basic system, plus:
AC FAILURE set to on.
LOW CPU BATTERY set to on.
AUTO PHONE TEST set to one.

Central Station Reporting

The panel has been tested with the following central station receivers using SIA and Contact ID
reporting formats:
CS-5000 Central Station Receiver.
Sur-Gard Central Station Receiver with models SG-DRL2A and SG-CPM2.
Osborne-Hoffman OH 2000 Central Station Receiver.

UL-Canada Listed Systems

This section describes the requirements for ULC (UL Canada) Listed systems.
1