Fire Panic (2Nd Tier); Rcvr Trouble (2Nd Tier); Panel Tamper (2Nd Tier); Exit Ext (2Nd Tier) - GE 60-874-95R Installation Instructions Manual

Hide thumbs Also See for 60-874-95R:
Table of Contents

Advertisement

Note
The fire panic alarm report
cannot be aborted or can-
celled.
Installer Programming Menus

FIRE PANIC (2nd Tier)

(Default = on)
This setting determines whether panel keypad fire panic buttons are enabled (on) or disabled
(off). If enabled, an immediate Fire alarm will occur after the fire panic buttons are pressed for
two seconds and the panel displays the alarm as a fire panic. If the DTIM is installed with the
system, an immediate alarm report will be issued.
¾
To turn the fire panic on or off:
Š Press # to turn on or off.

RCVR TROUBLE (2nd Tier)

(Default = off, UL installations = on)
When Receiver Trouble is on, the panel reports a receiver failure under the following condi-
tions:
A wireless sensor signal has not been received for two hours or
The receiver is being jammed with a constant signal.
¾
To turn receiver trouble reports on or off:
Š Press # to turn on or off.

PANEL TAMPER (2nd Tier)

(Default = on)
Panel Tamper determines how the panel handles possible tamper situations. When this feature
is on, the panel reports a panel tamper if the panel back cover or DTIM cover is opened while
the panel is armed. A police alarm will sound and
be displayed. If this feature is off or the system is disarmed the panel will display a status mes-
sage only.
¾
To turn the panel tamper on or off:
Š Press # to turn on or off.

EXIT EXT (2nd Tier)

(Default = on, UL installations = off)
When Exit Extension is on, the panel restarts the exit delay timer if the user re-enters the pre-
mises through a standard delay door before the standard exit delay time expires.
This helps prevent exit faults and false alarms by allowing users to re-enter the premises for a
forgotten item.
When this feature is off, the exit delay timer does not restart if the user re-enters the premises,
forcing the user to disarm the system to avoid setting off an accidental alarm.
¾
To turn exit extension on or off:
Š Press # to turn on or off.

SWINGER SHUTDOWN (2nd Tier)

(Default = 1, Parameters = 1-2)
This setting determines the maximum number of times a sensor or zone can go into alarm (dur-
ing a single arming period) before the panel automatically bypasses that sensor or zone. This
feature applies to all sensors groups except the fire (26), DTIM (29), and special chime (25)
groups.
When set to 1, the panel automatically bypasses a sensor or zone after it causes an alarm. When
set to 2, the panel waits until a sensor or zone has caused a second alarm (during the same arm-
ing period) before bypassing it.
Changing the arming level also clears all bypassed sensors and zones and resets the Swinger
Limit count on all sensors and zones.
¾
To set the swinger shutdown:
Š Press #, enter desired number and then press #.
or
PANEL TAMPER
PHONE MODULE TAMPER
(OPTIONS—)
(OPTIONS—)
(OPTIONS—)
will
(OPTIONS—)
(OPTIONS—)
17