No.
Name
Check marks (
) represent characteristics present in a group.
* This group is not certified as a primary protection circuit for UL-listed systems and is for supplementary use only.
† Sounds instant police siren if two or more sensors are tripped within 4 minutes. Otherwise sensors are followers to
delayed
sensors. If Alarm Verification is on, group 18 functions like group 17.
‡ This group has not been investigated by UL.
a The DTIM will report in all levels.
Siren Type:
Police - A high level steady siren.
Fire - A high level temporal siren.
Silent -No siren.
Emergency - A low level on-off patterned siren.
Delay:
Instant -A sensor of this type will cause an immediate alarm if a violation occurs anytime in an active arming level.
Standard - A sensor of this type will cause an entry delay if a violation occurs anytime in active arming level. A violation
during an exit delay will not cause an alarm.
If the arming level modifier No Delay is enabled a sensor of this type will cause an immediate alarm if the violation occurs
during an active arming level.
Follower - A sensor of this type will cause an immediate alarm if a violation occurs during an active level unless an entry
or exit delay is in progress. If violated during an entry delay and the entry delay expires the sensor will go into alarm.
Menu Name
Account
Number 1
FMT - CID/SIA
High LVL
Low LVL
Openings
Closings
Number 2
FMT - CID
High LVL
Low LVL
Openings
Closings
Backup
Dial DLY
Pre-dial String
DTMF Dial
Number
DL Code
Install Code
Dealer Code
Duress Code
Manager Code
34
Table B7: Sensor Group Characteristics (Continued)
Application
Table B8: System Settings
Default
00-000
4-10 digits; 0-9, A-F
none
24 digits; 0-9, *, #, pause
CID
On=CID, Off=SIA
On
off, on
On
off, on
Off
off, on
Off
off, on
none
24 digits; 0-9, *, #, pause
CID
On=CID, Off=SIA
Off
off, on
Off
off, on
Off
off, on
Off
off, on
On
off, on
30
15-120
none
8 digits; 0-9, *, #, pause
On
off, on
none
24 digits; 0-9, *, #, pause
12345
5 digit code, 0-9
4321
4 digit code, 0-9
none
4 digit code, 0-9
none
4 digit code, 0-9
none
4 digit code, 0-9
Alarm
Delay
Parameters
Appendix B: Reference Tables
Active
Levels
Settings

Hide quick links: