10.2.4.10
Diagnostic value '12.PST - Monitoring of partial stroke test'................................................203
10.2.4.11
10.2.4.12
Diagnostic value '14.NXPST - Time until next partial stroke test'........................................205
10.2.4.13
Diagnostics value '15.DEVI - Dynamic control valve behavior'............................................205
10.2.4.14
Diagnostic value '16.ONLK - Pneumatic leakage'................................................................205
10.2.4.15
Diagnostic value '17.STIC - Stiction (slipstick)'....................................................................205
10.2.4.16
Diagnostic value '18.ZERO - Lower endstop'.......................................................................206
10.2.4.17
Diagnostic value '19.OPEN - Upper endstop'......................................................................206
10.2.4.18
Diagnostic value '20.PAVG - Average value of position'......................................................206
10.2.4.19
Potentiometer value of upper endstop (100%)'....................................................................207
10.2.4.20
10.2.4.21
Diagnostic value '25.PAUTP - Pulse interval'.......................................................................209
10.2.4.22
10.2.4.23
10.2.4.24
Diagnostic value '30.TEMP - Current temperature'..............................................................210
10.2.4.25
10.2.4.26
Diagnostic value '33.T1' ... '41.T9' - Number of operating hours in the temperature range
10.2.4.27
Diagnostic value '42.VENT1' / '43.VENT2' ..........................................................................210
10.2.4.28
Diagnostic value '44.VEN1R' / '45.VEN2R'..........................................................................211
10.2.4.29
Diagnostic value '46.STORE - Save maintenance data'......................................................212
10.2.4.30
10.2.4.31
Diagnostic value '49.WT00' ... '56.WT95' - Number of operating hours in the travel range
WT00 to WT95.....................................................................................................................212
10.2.4.32
10.2.4.33
10.2.4.34
Diagnostic value '59.mA - Setpoint current'.........................................................................213
10.3
Online diagnostics................................................................................................................214
10.3.1
Overview of error codes (HART/PA)....................................................................................214
10.3.2
Overview of online diagnostics.............................................................................................216
10.3.3
XDIAG parameter ................................................................................................................216
10.3.4
Meaning of error codes........................................................................................................217
10.3.4.1
1 Remaining control deviation..............................................................................................217
10.3.4.2
2 Device not in "Automatic" mode........................................................................................217
10.3.4.3
3 Binary input BIN1 or BIN2 active.......................................................................................217
10.3.4.4
4 Monitoring the number of total strokes..............................................................................217
10.3.4.5
5 Monitoring the number of changes in direction.................................................................217
10.3.4.6
6 Monitoring the lower endstop / 7 Monitoring the upper endstop.......................................218
10.3.4.7
8 Monitoring deadband........................................................................................................218
10.3.4.8
9 Partial stroke test..............................................................................................................218
10.3.4.9
10 Monitoring of dynamic control valve behavior.................................................................219
10.3.4.10
11 Monitoring/compensation of pneumatic leakage ............................................................219
10.3.4.11
12 Monitoring of stiction (slipstick).......................................................................................219
10.3.4.12
13 Monitoring the lower limit temperature............................................................................219
10.3.4.13
14 Monitoring the upper limit temperature...........................................................................219
10.3.4.14
15 Monitoring the position average value............................................................................219
10.3.4.15
10.4
Fault correction....................................................................................................................220
10.4.1
Fault identification................................................................................................................220
10.4.2
Remedial measures table 1.................................................................................................221
SIPART PS2 with and without HART
Operating Instructions, 05/2017, A5E00074631-AC