Each of the 16 digital I/Os can be parameterized channel-by-channel as a digital input (DI),
digital output (DO), measuring input input, or an output cam output.
TM17 High Feature has fewer I/O channels than TM15, but more functionality. TM17 High
Feature is distinguished by especially high resolution and accuracy as well as a
parameterizable input filter and enabling inputs (max. 6 units). Parameterized enable inputs
can enable measuring inputs or outputs of output cams (gate function). Due to their high
accuracy, the digital I/O channels of the TM17 High Feature are non-isolated.
Note
NOTICE
Overheating if ventilation clearances are too small
Insufficient ventilation clearances result in overheating and therefore in more failures and a
shortened life of the component.
Maintain 50 mm ventilation clearances above and below the component.
Additional references
You will find further information on TM15 and TM17 High Feature in the
7.10

CUA31/CUA32 control unit adapter

Characteristics of the CUA31/CUA32
You can connect Power Modules in blocksize format via DRIVE‑CLiQ to the D4x5‑2 Control
Units using the CUA31/CUA32 adapter modules.
The CUA32 adapter module also has an additional encoder interface for an HTL, TTL, or SSI
encoder.
Table 7-39
Interface
DRIVE-CLiQ interface
EP terminals/temperature sensor connection
Power module interface (PM‑IF)
24 V electronic power supply
SIMOTION D4x5-2
Manual, 04/2014
TM15 / TM17 High Feature Terminal Modules Manual
Terminal Modules TM15 and TM17 High Feature Commissioning Manual
Number of interfaces on the adapter modules
Supplementary system components
7.10 CUA31/CUA32 control unit adapter
CUA31
CUA32
1)
3
3
1
1
1
1
1
1
133