TM17 High Feature
Each of the 16 digital I/Os can be parameterized channel-by-channel as a digital input (DI),
digital output (DO), measuring input input, or an output cam output.
TM17 High Feature has fewer I/O channels than TM15, but more functionality. TM17 High
Feature is distinguished by especially high resolution and accuracy as well as a
parameterizable input filter and enabling inputs (max. 6 units). Parameterized enable inputs
can enable measuring inputs or outputs of output cams (gate function). Due to their high
accuracy, the digital I/O channels of the TM17 High Feature are non-isolated.
Note
NOTICE
Overheating if ventilation clearances are too small
Insufficient ventilation clearances result in overheating and therefore in more failures and a
shortened life of the component.
Maintain 50 mm ventilation clearances above and below the component.
Additional references
You will find further information on TM15 and TM17 High Feature in the
●
●
7.10
CUA31/CUA32 control unit adapter
Characteristics of the CUA31/CUA32
You can connect Power Modules in blocksize format via DRIVE‑CLiQ to the D4x5‑2 Control
Units using the CUA31/CUA32 adapter modules.
The CUA32 adapter module also has an additional encoder interface for an HTL, TTL, or SSI
encoder.
Table 7-39
Interface
DRIVE-CLiQ interface
EP terminals/temperature sensor connection
Power module interface (PM‑IF)
24 V electronic power supply
SIMOTION D4x5-2
Manual, 04/2014
TM15 / TM17 High Feature Terminal Modules Manual
Terminal Modules TM15 and TM17 High Feature Commissioning Manual
Number of interfaces on the adapter modules
Supplementary system components
7.10 CUA31/CUA32 control unit adapter
CUA31
CUA32
1)
3
3
1
1
1
1
1
1
133