Panasonic AFPE224300 User Manual page 92

Fp-e series panel mounted controller
Hide thumbs Also See for AFPE224300:
Table of Contents

Advertisement

Item
External input relay
(See Note 3.)
External output relay
(See Note 3.)
Internal relay
(See Note 2.)
Data register
(See Note 2.)
Timer/counter
set value area
Timer/counter
elapsed value area
(See Note 2.)
Special data register
Index register
Item
Master control relay points(MCR)
Number of labels (JP and LOOP)
Number of step ladders
Number of subroutiones
Number of interrupt programs
Item
Decimal constants
(Integral type)
Hexadecimal
constants
Decimal constants
(monorefined real
number)
9-12
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Number of
Memory area available for use
points
Matsushita
6 double
DWX0 - DWX11
words
6 double
DWY0 - DWY11
words
31 double
DWR0 -
words
DWR61
830 double
DDT0 -
words
DDT1658
72 double
DSV0 - DSV142
words
72 double
DEV0 - DEV142
words
56 double
DDT9000 -
words
DDT9110
1 double
DI0
words
32 points
64 labels
128 stages
16 subroutiones
7 programs (external:6,internal:1)
Matsushita
K – 32768 to K32767 (for 16-bit operation)
K – 2147483648 to K2147483647
(for 32-bit operation)
H0 to HFFFF (for 16-bit operation)
H0 to HFFFFFFFF (for 32-bit operation)
–38
F – 1.175494 × 10
to F – 3.402823 × 10
–38
F1.175494 × 10
to F3.402823 × 10
IEC
Code for specifying 32 external
%ID0 -%ID11
input points as a double word
(32 bits) of data.
Code for specifying 32 external
%QD0 -
output points as double word
%QD11
(32 bits) of data.
Code for specifying 32 internal
%MD0.0 -
relay points as double word
%MD0.61
(32 bits) of data.
Data memory used in a program.
%MD5.0 -
Data is handled in 32-bit units
%MD5.1658
(double words).
Data memory for storing a target
%MD3.0 -
value of a timer and an initial value
%MD3.142
of a counter.
Stores by timer/counter number.
Data memory for storing the
%MD4.0 -
elapsed value during operation of a
%MD4.142
timer/counter.
Stores by timer/counter number.
Data memory for storing specific
%MD5.9000 -
data. Various settings and error
%MD5.9110
codes are stored.
Used as an address of memory
%MD6.0
area and constants modifier.
Number of points
Range available for use
– 32768 to 32767 (for 16-bit operation)
– 2147483648 to 2147483647
(for 32-bit operation)
16#0 to 16#FFFF (for 16-bit operation)
16#0 to 16#FFFFFFFF
(for 32-bit operation)
38
– 1.17549410E-38 to – 3.402823E38
38
1.17549410E-38 to 3.402823E38
Function
IEC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Afpe224305Afpe224322Afpe224302Afpe214325

Table of Contents