9.3 Relays,memory Areas and Constants

Item
External input relay
(See Note 3.)
External output relay
(See Note 3.)
Internal relay
(See Note 2.)
Timer
(See Notes 1 and 2.)
Counter
(See Notes 1 and 2.)
Special internal relay
External input relay
(See Note 3.)
External output relay
(See Note 3.)
Internal relay
(See Note 2.)
Data register
(See Note 2.)
Timer/counter
set value area
Timer/counter
elapsed value area
(See Note 2.)
Special data register
Index register
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Number of
Memory area available for use
points
Matsushita
208
X0 - X12F
208
Y0 - Y12F
1008
R0 - R62F
T0 -T99/
100
C100 - C143
C100 -C143/
44
T0 - T99
64
R9000 - R903F
13 words
WX0 - WX12
13 words
WY0 - WY12
63 words
WR0 - WR62
1660 words
DT0 - DT1659
144 words
SV0 - SV143
144 words
EV0 - EV143
DT9000 -
112 words
DT9111
2 words
IX - IY
IEC
%IX0.0 -
Turns on or off based on external
%IX12.15
input.
%QX0.0 -
Outputs on or off state externally.
%QX12.15
%MX0.0 -
Turns on or off only within a
%MX0.62.15
program.
%MX1.0 -
Turns on when the timer reaches
%MX1.99/
the specified time.
%MX2.100 -
Corresponds to the timer number.
%MX2.143
%MX2.100 -
Turns on when the counter
%MX2.143/
increments.
%MX1.0 -
Corresponds to the counter number.
%MX1.99
%MX0.900.0 -
Turns on or off based on specific
%MX0.903.15
conditions. Used as a flag.
Code for specifying 16 external
%IW0 -
input points as one word (16 bits)
%IW12
of data.
Code for specifying 16 external
%QW0 -
output points as one word (16 bits)
%QW12
of data.
Code for specifying 16 internal
%MW0.0 -
relay points as one word (16 bits)
%MW0.62
of data.
Data memory used in a program.
%MW5.0 -
Data is handled in 16-bit units (one
%MW5.1659
word).
Data memory for storing a target
value of a time and an initial value
%MW3.0 -
%MW3.143
of a counter. Stores by
time/counter number.
Data memory for storing the
%MW4.0 -
elapsed value during operation of a
%MW4.143
timer/counter. Stores by
time/counter number.
Data memory for storing specific
%MW5.9000 -
data. Various settings and error
%MW5.9111
codes are stored.
%MW6.0 -
Used as an address of memory
%MW6.1
area and constants modifier.
Function
9-11