Configuring Power Supply Options Using Idrac Settings Utility; Enabling Or Disabling Power Button - Dell iDRAC7 User Manual

Table of Contents

Advertisement

System.Power.RedundancyPolicy
System.Power.Hotspare.Enable
System.Power.Hotspare.PrimaryPSU
System.Power.PFC.Enable
For more information, see the
support/manuals.

Configuring Power Supply Options Using iDRAC Settings Utility

To configure the power supply options:
1.
In iDRAC Settings utility, go to Power Configuration.
NOTE: The Power Configuration link is available only if the server power supply unit supports power
monitoring.
The iDRAC Settings Power Configuration page is displayed.
2.
Under Power Supply Options:
Enable or disable power supply redundancy.
Enable or disable hot spare.
Set the primary power supply unit.
Enable or disable power factor correction. For more information about the options, see the
Utility Online Help .
3.
Click Back, click Finish, and then click Yes.
The power supply options are configured.

Enabling or Disabling Power Button

To enable or disable the power button on the managed system:
1.
In iDRAC Settings utility, go to Front Panel Security.
The iDRAC Settings Front Panel Security page is displayed.
2.
Select Enabled to enable the power button. Else, select Disabled.
3.
Click Back, click Finish, and then click Yes. The settings are saved.
RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell.com/