Configuring Email Alert, Snmp Trap, Or Ipmi Trap Settings; Configuring Ip Alert Destinations - Dell iDRAC7 User Manual

Table of Contents

Advertisement

eventfilters command.
cfgIpmiPefAction object with config command.
For more information, see the
support/manuals.

Configuring Email Alert, SNMP Trap, or IPMI Trap Settings

The management station uses Simple Network Management Protocol (SNMP) and Intelligent Platform Management
Interface (IPMI) traps to receive data from iDRAC7. For systems with large number of nodes, it may not be efficient for a
management station to poll each iDRAC7 for every condition that may occur. For example, event traps can help a
management station with load balancing between nodes or by issuing an alert if an authentication failure occurs.
You can configure the IPv4 and IPv6 alert destinations, email settings, and SMTP server settings, and test these settings.
Before configuring the email, SNMP, or IPMI trap settings, make sure that:
You have Configure RAC permission.
You have configured the event filters.
Related Links

Configuring IP Alert Destinations

Configuring Email Alert Settings
Configuring IP Alert Destinations
You can configure the IPv6 or IPv4 addresses to receive the IPMI alerts or SNMP traps.
Configuring IP Alert Destinations Using Web Interface
To configure alert destination settings using Web interface:
1.
Go to Overview → Server → Alerts → SNMP and E-mail Settings.
2.
Select the State option to enable an alert destination (IPv4 address, IPv6 address, or Fully Qualified Domain Name
(FQDN)) to receive the traps.
You can specify up to eight destination addresses. For more information about the options, see the
Help .
3.
Enter the iDRAC7 SNMP community string and the SNMP alert port number.
For more information about the options, see the
NOTE: The Community String value indicates the community string to use in a Simple Network Management
Protocol (SNMP) alert trap sent from iDRAC7. Make sure that the destination community string is the same as
the iDRAC7 community string. The default value is Public.
4.
To test whether the IP address is receiving the IPMI or SNMP traps, click Send under Test IPMI Trap and Test
SNMP Trap respectively.
5.
Click Apply.
The alert destinations are configured.
6.
In the SNMP Trap Format section, select the protocol version to be used to send the traps on the trap destination(s)
— SNMP v1 or SNMP v2 and click Apply.
NOTE: The SNMP Trap Format option applies only for SNMP Traps and not for IPMI Traps. IPMI Traps are
always sent in SNMP v1 format and is not based on the configured SNMP Trap Format option.
The SNMP trap format is configured.
RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell.com/
iDRAC7 Online Help .
iDRAC7 Online
155

Advertisement

Table of Contents
loading

Table of Contents