Siemens SIWAREX WP231 Manual page 90

Hide thumbs Also See for SIWAREX WP231:
Table of Contents

Advertisement

Scale parameters and functions
8.8 DR 7 interface parameters
Variable
Note
Analog output
Basis of analog value output:
source
0 = G/N value
(Page 94)
1 = Gross
2 = Net
3 = Ext. specification, DR 17
4 = Ext. specification, S7
interface
Response of
0: Switch off
analog output to
1: Continue
faults or
2: Output configured output
SIMATIC STOP
value
(Page 94)
3: Output maximum value
(24 mA, NAMUR)
Start value for
Value at which 0 ...4 mA is
the analog
to be output
output (Page 94)
End value for
Value at which 20 mA is to
the analog
be output
output (Page 94)
Output value
Value to be output when the
following fault or
OutDis signal is enabled (in
SIMATIC STOP
mA)
(Page 95)
Trace recording
1: 10 ms
cycle (Page 95)
10: 100 ms
100: 1 s
1 000: 10 s
Trace storage
0: Trace recording runs as a
method, bit 0
circular buffer
1: Trace is stopped when the
trace memory is full
Bit 1
Reserve
Bit 2
Reserve
Bit 3
Reserve
Bit 4
Reserve
Bit 5
Reserve
Bit 6
Reserve
Bit 7
Reserve
Bit 8
Reserve
Bit 9
Reserve
Bit 10
Reserve
Bit 11
Reserve
Bit 12
Reserve
Bit 13
Reserve
Bit 14
Reserve
Bit 15
Reserve
Reserve 1
Reserve
Reserve 2
Reserve
90
Type
Length
RW
(bytes)
USHORT 2
rw
USHORT 2
rw
FLOAT
4
rw
FLOAT
4
rw
FLOAT
4
rw
USHORT 2
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
1
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
1
rw
LONG
4
rw
FLOAT
4
rw
Default
Min.
Max.
2
0
3
0
0
3
0
maximum
maxi-
weighing
mum
range
weigh-
ing
range
0
maximum
maxi-
weighing
mum
range
weigh-
ing
range
0
0
24
1
1
1000
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
0
0
Manual, 07/2014, A5E31238908A-02
Modbus
Register
1316
1317
1318
1320
1322
1324
1325.16
1325.15
1325.14
1325.13
1325.12
1325.11
1325.10
1325.9
1325.8
1325.7
1325.6
1325.5
1325.4
1325.3
1325.2
1325.1
-
1326
-
1328