Siemens SIWAREX WP231 Manual page 142

Hide thumbs Also See for SIWAREX WP231:
Table of Contents

Advertisement

Command lists
10.2 Command lists
Command
code
715
716
801
802
860
861
862
863
864
865
870
871
875
876
881
882
883
884
891
Reserve
Reserve
Reserve
142
Command
G process value (no write protec-
tion)
G process value after filter 2
Display currently set calibration
regulation /country code
Display weighing range data
Hide display
Legal trade display for variant 1
Legal trade display for variant 2
Legal trade display for variant 3
Legal trade display for variant 4
Legal trade display for variant 5
Display smallest representation of
legal trade display
Display current serial number
Display FW version
Display SecureDisplay software
version
Display first logbook entry
Display last logbook entry
Display reading of previous entry
Display reading of subsequent
entry
Display log entry (DS46)
Description
Display gross process weight on main display,
only permitted if OIML R76 is not set as the
regulation code (main display and SecureDis-
play)
Display gross process weight (commissioning)
on main display, only permitted if OIML R76 is
not set as the regulation code (main display
and SecureDisplay)
Display currently set calibration regulation
temporarily on the main display (main display
and SecureDisplay), for duration of 5 s
Display weighing range data (min., max., digit
step) in the legal trade display SecureDisplay
(for duration of 10 s)
Hides the legal trade display SecureDisplay
Acts on the legal trade display SecureDisplay.
Enables version 1 for display size and position
according to DisplayCali.xml file
Acts on the legal trade display SecureDisplay.
Enables version 1 for display size and position
according to DisplayCali.xml file
Acts on the legal trade display SecureDisplay.
Enables version 1 for display size and position
according to DisplayCali.xml file
Acts on the legal trade display SecureDisplay.
Enables version 1 for display size and position
according to DisplayCali.xml file
Acts on the legal trade display SecureDisplay.
Enables version 1 for display size and position
according to DisplayCali.xml file
Shows the smallest possible display of the
SecureDisplay according to parameter "Min.
zoom factor Display%" in DR3
Display serial number of SIWAREX temporarily
on the main display and SecureDisplay, for
duration of 5 s
Display current firmware version of module on
SecureDisplay
The first logbook entry is displayed on the
SecureDisplay.
The last logbook entry is displayed on the
SecureDisplay.
The logbook entry prior to the last read entry is
displayed on the SecureDisplay.
The logbook entry after the last read entry is
displayed on the SecureDisplay.
The log entry requested in DS45 is displayed
on the SecureDisplay, for duration of 10 s.
Manual, 07/2014, A5E31238908A-02
Protected
P
P
SIWAREX WP231

Advertisement

Table of Contents
loading