VEGAMET 391 • 4 ... 20 mA/HART
triggered. In case of an instrument defect or line break/shortcircuit, a
fault signal is also triggered.
The fault indication lights up in case of failure and the current output
as well as the relays react according to the configured fault mode. If
the fail safe relay was configured, it will deenergize. In addition, one of
the following error messages is outputted on the display.
Error code
Cause
E003
CRC error (error with
self-check)
E007
Sensor type not com-
patible
E008
Sensor not found
E013
Sensor signals error,
no valid measured
value
E014
Sensor current
> 21 mA or short-
circuit
E015
Sensor in boot phase
Sensor current
< 3.6 mA or line
break
E016
Empty/full adjustment
reversed
E017
Adjustment span too
small
E021
Scaling span too
small
E030
Sensor in boot phase
Measured value not
valid
E034
EEPROM CRC error
E035
ROM CRC error
E036
Instrument software
not executable (dur-
ing software update
and after failed up-
date)
E053
Sensor measuring
range is not read cor-
rectly
9 Maintenance and fault rectification
Rectification
– Carry out a reset
– Send instrument for repair
– Search for sensor again and allocate
under "Meas. loop - Input"
– Check connection of the sensor
– Check HART address of the sensor
– Check sensor parameter adjustment
– Send sensor for repair
– Check sensor, e.g. on failure
– Remove short-circuit
– Check sensor, e.g. on failure
– Remove line break
– Check connection of the sensor
– Carry out a fresh adjustment
– Carry out a fresh adjustment and
increase the distance between min.
and max. adjustment
– Carry out a fresh scaling, increase
the distance between min. and max.
scaling.
– Check sensor parameter adjustment
– Switch the instrument off and on
– Carry out a reset
– Send instrument for repair
– Switch the instrument off and on
– Carry out a reset
– Send instrument for repair
– Wait until software update is finished
– Carry out another software update
– Communication error: Check sensor
cable and screening