Vega VEGAFLEX 83 Operating Instructions Manual

Tdr sensor for continuous level and interface measurement of liquids, 4...20 ma/hart - two-wire
Hide thumbs Also See for VEGAFLEX 83:

Advertisement

Operating Instructions

TDR sensor for continuous level and
interface measurement of liquids
VEGAFLEX 83
4 ... 20 mA/HART - two-wire
Document ID: 41834

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VEGAFLEX 83 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vega VEGAFLEX 83

  • Page 1: Operating Instructions

    Operating Instructions TDR sensor for continuous level and interface measurement of liquids VEGAFLEX 83 4 … 20 mA/HART - two-wire Document ID: 41834...
  • Page 2: Table Of Contents

    Parameter adjustment with PACTware ......46 Set up with the quick setup ..........47 Saving the parameter adjustment data ......51 Set up with other systems DD adjustment programs ..........52 Communicator 375, 475 ........... 52 VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 3 Please note the Ex-specific safety information for installation and op- eration in Ex areas. These safety instructions are part of the operating instructions manual and come with the Ex-approved instruments. Editing status: 2012-07-26 VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 4: About This Document

    This arrow indicates a single action. Sequence Numbers set in front indicate successive steps in a procedure. Battery disposal This symbol indicates special information about the disposal of bat- teries and accumulators. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 5: For Your Safety

    During work on and with the device the required personal protective equipment must always be worn. 2.2 Appropriate use VEGAFLEX 83 is a sensor for continuous level measurement. You can find detailed information on the application range in chapter "Product description".
  • Page 6: Namur Recommendations

    The environment management system is certified according to DIN EN ISO 14001. Please help us fulfil this obligation by observing the environmental instructions in this manual: • Chapter "Packaging, transport and storage" • Chapter "Disposal" VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 7: Product Description

    For this purpose, move to www.vega.com and "VEGA Tools". Scope of this operating This operating instructions manual applies to the following instrument instructions manual versions: • Hardware from 1.0.0 • Software from 1.0.0 VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 8: Principle Of Operation

    – if necessary, further certificates 3.2 Principle of operation Application area The VEGAFLEX 83 is a level sensor with coated cable or rod probe for continuous level or interface measurement, particularly suitable for applications in the chemical industry. Functional principle -...
  • Page 9 The dielectric constant of the upper medium must be known (input required). Min. dielectric constant: rod version 1.6. You can find a list with the dielectric constants on our home page: www.vega.com • The composition of the upper medium must be stable, no varying products or mixtures •...
  • Page 10: Packaging, Transport And Storage

    You can find further information in the operating instructions "Interface adapter VEGACONNECT" (Document-ID 32628). External indicating and VEGADIS 61 is an external indicating and adjustment unit for sensors adjustment unit with single chamber housing and Ex-d double chamber housing. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 11 If you are using an instrument with rod version, you can extend the rod probe individually with rod extensions of different lengths. The following lengths are available: • 100 mm • 200 mm • 500 mm VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 12 You can find further information in the operating instructions manual "Rod extension VEGAFLEX series 80". Spacer If you mount the VEGAFLEX 83 in a bypass tube or standpipe, you have to avoid contact to the bypass tube by using a spacer at the probe end.
  • Page 13: Mounting

    4.2 Instructions for installation Installation position Mount VEGAFLEX 83 in such a way that the distance to vessel instal- lations or to the vessel wall is at least 300 mm (12 in). In non-metallic vessels, the distance to the vessel wall should be at least 500 mm (19.7 in).
  • Page 14 If this is not possible, use short sockets with small diameter. Higher sockets or sockets with a bigger diameter can generally be used. They simply increase the upper blocking distance. Check if this is relevant for your measurement. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 15 By doing this, you avoid damage to the electronics through inductive coupling. Inflowing medium Do not mount the instruments in or above the filling stream. Make sure that you detect the product surface, not the inflowing product. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 16 If durability is no problem, then we recommend the use of metal standpipes. When the VEGAFLEX 83 is used in standpipes or bypass tubes, contact with the tube wall must be avoided. We recommend for this purpose a cable probe with centering weight.
  • Page 17 PTFE plated flanges. The flange screws of VEGAFLEX 83 must always be tightened with a torque of approx. 60 Nm (44 lbf ft) so that the PTFE washer seals reliably.
  • Page 18: Connecting To Power Supply

    Connection to signal con- The signal conditioning instruments VEGAMET and VEGASCAN ditioning instruments have digital sensor recognition. When connecting VEGAFLEX 83, an up-to-date version of the signal conditioning instrument software is required. For a software update go to "www.vega.com/downloads" and "Software".
  • Page 19: Connecting

    4. Remove approx. 10 cm (4 in) of the cable mantle, strip approx. 1 cm (0.4 in) of insulation from the ends of the individual wires 5. Insert the cable into the sensor through the cable entry VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 20: Wiring Plan, Single Chamber Housing

    11. Screw the housing cover back on The electrical connection is hence finished. 5.3 Wiring plan, single chamber housing The following illustration applies to the non-Ex as well as to the Ex-ia version. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 21: Wiring Plan, Double Chamber Housing

    The following illustrations apply to the non-Ex as well as to the Ex-ia version. Electronics compartment 4...20mA 6 7 8 Fig. 11: Electronics compartment, double chamber housing Internal connection to the connection compartment For indicating and adjustment module or interface adapter VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 22 Radio module PLICSMO- BILE integrated in the Status SIM-Card Test connection compartment Fig. 13: CConnection of the voltage supply of the radio module Voltage supply You can find detailed information for connection in the supplementary instructions "PLICSMOBILE GSM/GPRS radio module". VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 23: Wiring Plan, Ex-D-Ia Double Chamber Housing

    Fig. 16: Top view of the plug connector Pin 1 Pin 2 Pin 3 Pin 4 Contact pin Colour connection ca- Terminal, electronics ble in the sensor module Pin 1 Brown Pin 2 White Pin 3 Blue VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 24: Wiring Plan - Version Ip 66/Ip 68, 1 Bar

    As soon as a plausible measured value is found, the corresponding current is outputted to the signal cable. The value corresponds to the actual level as well as the settings already carried out, e.g. factory setting. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 25: Set Up With The Indicating And Adjustment Module

    The indicating and adjustment module is powered by the sensor, an additional connection is not necessary. Fig. 18: Insertion of the indicating and adjustment module with single chamber housing into the electronics compartment VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 26: Adjustment System

    6.2 Adjustment system Fig. 20: Indicating and adjustment elements 1 LC display Adjustment keys • Key functions [OK] key: – Move to the menu overview – Confirm selected menu VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 27: Parameter Adjustment

    "Setup" should be selected one after the other and provided with the correct parameters. If possible, go through the items in the given sequence. The procedure is described below. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 28 In this menu item you can enter the probe length or have the length determined automatically by the sensor system. When choosing "Yes", then the probe length will be determined automatically. When choosing "No", you can enter the probe length manually. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 29 Examples stant ≥ 10 Water-based liq- Acids, alcalis, water uids > 3 … < 10 Chemical mix- Chlorobenzene, nitro lacquer, aniline, tures isocyanate, chloroform ≤ 3 Hydrocarbons Solvents, oils, liquid gas VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 30 The distance refers to the sensor reference plane (seal surface of the process fitting). Keep in mind that the max. level must lie below the dead band. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 31 Interface urement under the menu item "Application". If you have selected "Yes" in the previous menu item (accept adjustment of the level measure- ment), then the actual setting will be displayed. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 32 Note the following, if the respective sensor is used as part of an over- fill protection system according to WHG: If a linearisation curve is selected, the measuring signal is no longer linearly proportional to the level. This must be taken into consideration VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 33 You can accept the scaling of the level measurement also for the interface measurement. If you select "Yes", the actual setting will be displayed. If you have selected "No", then you can enter the scaling for the interface separately. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 34 Setup/Current output In the menu item "Current output Min./Max.", you determine the reac- Min./Max. tion of the current output during operation. The default setting is min. current 3.8 mA and max. current 20.5 mA. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 35 Proceed as follows: Enter the actual distance from the sensor to the product surface. All interfering signals in this section are detected by the sensor and stored. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 36 The default setting for the displayed value 2 is the electronics tem- perature. Display/Backlight The optionally integrated background lighting can be adjusted via the adjustment menu. The function depends on the height of the supply voltage, see "Technical data". VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 37 "Setup/Application", then the peak values of the interface meas- urement are displayed in addition to the peak values of the level measurement. In another window you can carry out a reset of the two peak values separately. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 38 This allows the signal path to be tested, e.g. via downstream indicating instruments or the input card of the control system. Select the requested simulation size and adjust the requested value. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 39 In this menu item, the PIN is displayed or edited and changed. However, this menu item is only available if adjustment is enabled in the menu "Lock/Release setup/ adjustment". VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 40 The following table shows the default values of the instrument. De- pending on the instrument version or application, all menu items may not be available or some may be differently assigned: VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 41 The following data or settings for adjustment of the indicating and adjustment module are saved: • All data of the menu "Setup" and "Display" • In the menu "Additional adjustments" the items "Reset, Date/Time" • Special parameters VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 42 4 … 20 mA signal in Multidrop mode. In mode "Fix current (4 mA)" a fix 4 mA signal is outputted independ- ent from the actual level. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 43: Saving The Parameter Adjustment Data

    "Indicating and adjustment module" in the menu item "Copy sensor data". The data remain there permanently even if the sensor power supply fails. The following data or settings for adjustment of the indicating and adjustment module are saved: VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 44 If it is necessary to exchange a sensor, the indicating and adjustment module is inserted into the replacement instrument and the data are likewise written into the sensor via the menu item "Copy sensor data". VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 45: Setup With Pactware

    250 Ω), an additional external resistance is not necessary. This applies, e.g. to the VEGA instruments VEGATRENN 149A, VEGAMET 381, VEGAMET 391. Common Ex separators are also usually equipped with a sufficient current limitation resistance. In VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 46: Parameter Adjustment With Pactware

    An assistant for simple project configuration simplifies the adjustment considerably. Saving/printing the project as well as import/export functions are also part of the standard version. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 47: Set Up With The Quick Setup

    2 Extended adjustment Maintenance Quick setup With quick setup you can carry out the parameter adjustment of VEGAFLEX 83 for your application in just a few simple steps. The assistant-driven adjustment includes the basic settings for simple, reliable setup and commissioning. Information: If the function is inactive, then possibly no instrument is connected.
  • Page 48 If this function is inactive, the medium type your instrument is suitable for was already preset. Information: In special cases you can change the medium type. This setting can be changed under "Extended adjustment". VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 49 If you have selected interface measurement in the previous menu, then you can enter the values for the min. and max. adjustment of level and interface or accept the values of the level measurement. The VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 50 Prepare a backup file of the instrument parameter adjustment? For backup purposes, the current parameter adjustment of the instru- ment is stored in a file. You can use this file later on to restore the VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 51: Saving The Parameter Adjustment Data

    PIN is entered again. 7.4 Saving the parameter adjustment data We recommend documenting or saving the parameter adjustment data via PACTware. That way the data are available for multiple use or service purposes. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 52: Set Up With Other Systems

    8.2 Communicator 375, 475 Device descriptions for the instrument are available as DD or EDD for parameter adjustment with the Field Communicator 375 or 475. The files can be downloaded unter www.vega.com/downloads and "Software". VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 53: Diagnostics And Service

    The echo curve of the setup is stored via: • PC with PACTware/DTM • Control system with EDD • Indicating and adjustment module VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 54: Status Messages

    Plan in maintenance for the instrument because a failure is expected in the near future (e.g. due to buildup). This status message is inactive by default. It can be activated by the user via PACTware/DTM or EDD. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 55 F260 – Error in the calibration car- – Exchanging the electronics ried out in the factory – Send instrument for repair Error in the – Error in the EEPROM calibration VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 56 – Check level in the vessel Maintenance The following table shows the error codes and text messages in the status message "Maintenance" and provides information on causes as well as corrective measures. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 57: Rectify Faults

    Check the 4 … 20 mA Connect a handmultimeter in the suitable measuring range according signal to the wiring plan. The following table describes possible errors in the current signal and helps to remove them: VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 58 "Hold value" • In case of a too low level indication, the reason could be a line resistance that is too high VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 59 The time – If possible, switch off the func- max. level (0 m distance) as tion "Overfill protection" well as the status message "Overfill protection" are output- ted. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 60: Exchanging The Electronics Module

    24 hour service hotline Should these measures not be successful, please call in urgent cases the VEGA service hotline under the phone no. +49 1805 858550. The hotline is also available outside the normal working hours on seven days a week around the clock.
  • Page 61: Software Update

    Attach the completed form and, if need be, also a safety data sheet outside on the packaging • Please contact for the return shipment the agency serving you. You can find the agency on our home page www.vega.com. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 62: Dismounting

    Pass the instrument directly on to a spe- cialised recycling company and do not use the municipal collecting points. These may be used only for privately used products according to the WEEE directive. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 63: Supplement

    Ʋ Trimming accuracy - rod < 1 mm (0.039 in) Ʋ Cable: ø 4 mm (0.157 in) - PFA coated up to 32 m (105 ft) Ʋ Trimming accuracy - cable ±0.05 % VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 64 Upper dead band (see diagrams under Accuracy - grey section) Lower dead band (see diagrams under Accuracy - grey section) Output variable Output signal 4 … 20 mA/HART Fulfilled HART specification Signal resolution 0.3 µA VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 65 Depending on the installation conditions, there can be deviations which can be rectified with an adaptation of the adjustment or a change of the measured value offset in the DTM service mode The dead bands can be optimizes by a false signal suppression. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 66 -15 mm (-0.591 " 0,2 m 0,35 m 0,05 m (7.874 (13.78 " ") (1.969 ") 0,1 m (3.937 ") Fig. 37: Deviation VEGAFLEX 83 in rod version (coated) in oil Dead band - no measurement possible in this area Probe length VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 67 ±3 mm/10 K relating to the max. measuring range or max. 10 mm (0.394 in) Additional deviation through strong, high < ±10 mm (< ±0.394 in) frequency electromagnetic fields acc. to EN 61326 VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 68 Time span after a sudden measuring distance change by max. 0.5 m in liquid applications, max 2 m with bulk solids applications, until the output signal has taken for the first time 90 % of the final value (IEC 61298-2). VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 69 0.2 … 2.5 mm² (AWG 24 … 14) Ʋ Stranded wire with end sleeve 0.2 … 1.5 mm² (AWG 24 … 16) Electromechanical data - version IP 66/IP 68 (1 bar) Options of the cable entry VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 70 Integrated clock Date format Day.Month.Year Time format 12 h/24 h Time zone Ex factory Measurement electronics temerature Resolution 1 °C (1.8 °F) Accuracy ±1 °C (1.8 °F) Voltage supply Operating voltage VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 71 Ʋ Aluminium and stainless housing, in- IP 66/IP 68 (1 bar) vestment casting (optionally available) Overvoltage category The prerequisites for maintaining the protection rating are a suitable cable as well as correct mounting. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 72: Dimensions

    Instruments with approvals can have different technical data depending on the version. That's why the associated approval documents of these instruments have to be carefully noted. They are part of the delivery or can be downloaded under www.vega.com and "VEGA Tools" as well as under "Downloads" and "Approvals".
  • Page 73 ø 79 mm (3.39") (3.15") (3.11") M16x1,5 M20x1,5/ ½ NPT M20x1,5/ M20x1,5/ ½ NPT ½ NPT Fig. 45: Housing versions in protection IP 66/IP 68 (0.2 bar) - with integrated indicating and adjustment module the housing is 9 mm/0.35 in higher Single chamber version, electropolished Single chamber version, precision casting Double chamber version, precision casting VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 74 ø 80 mm ø 77 mm (3.31") (3.15") (3.03") M16x1,5 M20x1,5 M20x1,5/ ½ NPT M20x1,5/ ½ NPT Fig. 46: Housing versions in protection IP 66/IP 68 (1 bar) - with integrated indicating and adjustment module the housing is 9 mm/0.35 in higher Single chamber version, electropolished Single chamber version, precision casting Double chamber version, precision casting VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 75 11 Supplement VEGAFLEX 83, cable version ø 4 mm (0.157 in) - PFA coated ø 4 mm (0.16") ø 20 mm (0.79") Fig. 47: VEGAFLEX 83, cable version with gravity weight Sensor length, see chapter "Technical data" Cable version, ø 4 mm (0.157 in) with flange Cable version with Clamp Cable version with bolting VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 76 11 Supplement VEGAFLEX 83, rod version ø 10 mm (0.394 in) - PFA coated ø 10 mm (0.39") Fig. 48: VEGAFLEX 83, rod version Sensor length, see chapter "Technical data" Rod version, ø 10 mm (0.394 in) with flange Rod version with Clamp Rod version with bolting VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 77 Линии продукции фирмы ВЕГА защищаются по всему миру правами на интеллектуальную собственность. Дальнейшую информацию смотрите на сайте VEGA系列产品在全球享有知识产权保护。 进一步信息请参见网站< >。 11.4 Trademark All the brands as well as trade and company names used are property of their lawful proprietor/ originator. VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 78 Electronics and connection compartment, single chamber housing 21 Electronics compartment, double chamber Packaging 10 housing 21 Peak value 37, 38 Electronics compartment with Ex-d double PIN 39 chamber housing 23 Potential equalisation 19 VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 79 Scaling measured value 33, 34 Sensor characteristics 43 Sensor status 37 Service hotline 60 Shielding 18 Simulation 38 Special parameters 42 Status messages 54 Storage 10 Type label 7 Units 28 Voltage supply 18 VEGAFLEX 83 • 4 … 20 mA/HART - two-wire...
  • Page 80 Subject to change without prior notice © VEGA Grieshaber KG, Schiltach/Germany 2012 VEGA Grieshaber KG Phone +49 7836 50-0 Am Hohenstein 113...

Table of Contents