Item
2
3
4
5
6
7
8
9

AMS 2300 Rev2 Fibre channel control unit RKEM

As described earlier, the controllers in each model base unit are different.
The main differences between the control units is the number of Fibre
Channel ports and the amount of cache memory (RAM) installed in the
LED
When adding the chassis with the power turned on, indicates
the addition source (not an error).
Determine the type of error by the number of times the LED
blinks.
• Not blinking: Boot section error of ENC microprogram, RAM
error, or ENC hard configuration error.
LOC
• 1: SRAM error
(orange)
• 2: ENC hard error
• 3: Microprogram error in flash memory
• 4: CUDG error in ENC
• 6: Voltage on the control unit is abnormal. Reset of the
control unit is not canceled.
RST
ON: the control unit is resetting.
(orange)
C-PWR
ON: cache memory is backed up.
(green)
ACT/Active
ON: data is being transferred.
(yellow)
LINK
ON: the link status is normal.
(green)
HALM
ON: the host connector is abnormal.
GP1
ON: the status of the interface is normal.
(green)
GP0
ON: the status of the interface is normal.
(green)