B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 39 of 59)
ADDR
REGISTER NAME
Undercurrent (Read/Write Grouped Setting)
9F00
Undercurrent Function
9F01
Undercurrent Speed 1 Start Block Delay
9F02
Undercurrent Speed 1 Alarm Pickup
9F03
Undercurrent Speed 1 Alarm Pickup Delay
B
9F04
Undercurrent Speed 1 Trip Pickup
9F05
Undercurrent Speed 1 Trip Pickup Delay
9F06
Undercurrent Speed 1 Trip Reset Delay
9F07
Undercurrent Speed 1 Block
9F08
Undercurrent Target
9F09
Undercurrent Events
9F0A
Undercurrent Speed 2 Start Block Delay
9F0B
Undercurrent Speed 2 Alarm Pickup
9F0C
Undercurrent Speed 2 Alarm Pickup Delay
9F0D
Undercurrent Speed 2 Trip Pickup
9F0E
Undercurrent Speed 2 Trip Pickup Delay
9F0F
Undercurrent Speed 2 Trip Reset Delay
9F10
Undercurrent Speed 2 Block
9F11
Reserved (2 items)
Broken Rotor Bar Detection (Read Only Actual Values)
A020
Broken Rotor Bar Component Level
A021
Broken Rotor Bar Component Frequency
A022
Motor Load at Broken Rotor Bar Calculation
A023
Motor Load Deviation at Broken Rotor Bar Calculation
A024
Time Stamp at Broken Rotor Bar Calculation
A026
Maximum Broken Rotor Bar Component Level
A027
Maximum Broken Rotor Bar Component Frequency
A028
Motor Load at Broken Rotor Bar Maximum
A029
Motor Load Deviation at Broken Rotor Bar Maximum
A02A
Time Stamp at Broken Rotor Bar Maximum
Broken Rotor Bar Commands (Read/Write Commands)
A02D
Broken Rotor Bar Clear Data Command
Broken Rotor Bar Detection (Read/Write Settings)
A030
Broken Rotor Bar Function
A031
Start of Broken Rotor Bar Offset
A032
End of Broken Rotor Bar Offset
A033
Broken Rotor Bar Start Block Delay
A034
Minimum Motor Load
A035
Maximum Load Deviation
A036
Maximum Current Unbalance
A037
Broken Rotor Bar Pickup
A038
Broken Rotor Bar Reset Delay
A039
Broken Rotor Bar Block
A03A
Broken Rotor Bar Target
A03B
Broken Rotor Bar Events
VT Fuse Failure (Read/Write Setting) (6 modules)
A040
VT Fuse Failure 1 Function
A041
...Repeated for VT Fuse Failure 2 Function
A042
...Repeated for VT Fuse Failure 3 Function
A043
...Repeated for VT Fuse Failure 4 Function
A044
...Repeated for VT Fuse Failure 5 Function
A045
...Repeated for VT Fuse Failure 6 Function
Current Unbalance Actual Values (Read Only)
A200
Current Unbalance
B-46
RANGE
0 to 1
0 to 600
0.1 to 0.95
0 to 600
0.1 to 0.95
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 600
0.1 to 0.95
0 to 600
0.1 to 0.95
0 to 600
0 to 600
0 to 65535
0 to 1
–100 to 0
0 to 76
0 to 1.5
0 to 1.5
0 to 4294967295
–100 to 0
0 to 76
0 to 1.5
0 to 1.5
0 to 4294967295
0 to 1
0 to 1
–12 to 11.99
–11.99 to 12
0 to 600
0.5 to 1
0 to 1
0 to 100
–60 to –12
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 100
M60 Motor Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F102
s
0.01
F001
× FLA
0.01
F001
s
0.01
F001
× FLA
0.01
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
s
0.01
F001
× FLA
0.01
F001
s
0.01
F001
× FLA
0.01
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F001
dB
0.1
F002
Hz
0.01
F001
× FLA
0.01
F001
× FLA
0.01
F001
---
1
F050
dB
0.1
F002
Hz
0.01
F001
× FLA
0.01
F001
× FLA
0.01
F001
---
1
F050
---
1
F126
---
1
F102
Hz
0.01
F002
Hz
0.01
F002
s
0.01
F001
× FLA
0.01
F001
× FLA
0.01
F001
%
0.1
F001
dB
1
F002
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
%
0.1
F001
DEFAULT
0 (Disabled)
50
70
200
70
100
100
0
0 (Self-reset)
0 (Disabled)
50
70
200
70
100
100
0
0
–1000
0
0
0
0
–1000
0
0
0
0
0 (No)
0 (Disabled)
40
200
6000
70
10
150
-40
0
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
0