Racreset - Dell PowerEdge M1000e Reference Manual

Chassis management controller version 5.0 for dell poweredge m1000e racadm command line
Hide thumbs Also See for PowerEdge M1000e:
Table of Contents

Advertisement

Power Status
===============================================================================
Session Information
===============================================================================
Type
User
IP Address
SSH
root
10.9.72.252
KVM
root
169.254.31.30
===============================================================================
Sensor Information
===============================================================================
<senType> <Num> <sensorName> <status> <reading> <units> <lc>
<uc>
FanSpeed
1
Fan-1
FanSpeed
2
Fan-2
FanSpeed
3
Fan-3
FanSpeed
4
Fan-4
FanSpeed
5
Fan-5
FanSpeed
6
Fan-6
FanSpeed
7
Fan-7
FanSpeed
8
Fan-8
FanSpeed
9
Fan-9
<senType> <Num> <sensorName> <status> <reading> <units> <lc>
<uc>
Temp
1
Ambient_Temp
<senType> <Num>
<sensorName>
PWR
1
PWR
2
PWR
3
PWR
4
PWR
5
PWR
6

racreset

Resets CMC. The reset event is logged in the hardware (SEL) and CMC (RAC) logs.
Description
To run this subcommand, you must have the Chassis Administrator privilege.
racadm racreset [-m <module> [-f]]
Synopsis
-m — The values must be one of the following:
Input
– server–<n> — where n=1–16
– server–<nx> — where n=1–8; x = a, b, c, d (lower case)
= ON
Login Date/Time
11/28/2007 23:40:53
11/28/2007 18:44:51
OK
OK
OK
OK
OK
OK
OK
Not OK
OK
OK
<status>
PS-1
Online
PS-2
Online
PS-3
Online
PS-4
Slot Empty
PS-5
Failed
PS-6
Slot Empty
NOTE: After you run the racreset subcommand, CMC may require up to two minutes to return to a
usable state.
NOTE: There is a 100 percent fan request when the command is run against the servers.
NOTE:
– Multiple modules may be specified, such as -m <module1> -m <module 2>.
– -f option is used to force the reset and is available only with an -m option.
14495
rpm
7250 14500
14505
rpm
7250 14500
4839
rpm
2344 14500
14527
rpm
7250 14500
14505
rpm
7250 14500
4835
rpm
2344 14500
14521
rpm
7250 14500
1
rpm
7250 14500
4826
rpm
2344 14500
21
celcius
N/A
<AC-OK status>
OK
OK
OK
N/A
OK
N/A
40
61

Hide quick links: