cfgChassisDefaultPowerCapLowerBound (Read Only)

Displays the default power cap lower bound value.
Description
None
Legal Values
2715 W
Default

cfgChassisDefaultPowerCapUpperBound (Read Only)

Displays the default power cap upper bound value.
Description
None
Legal Values
16685 W
Default

cfgChassisDefaultPowerCapUpperBoundBTU (Read or Write)

Displays the default power cap upper bound value using British Thermal Unit (BTU).
Description
None
Legal Values
56931 BTU/h
Default
cfgChassisPowerCap (Read or Write)
Indicates the maximum power consumption limit (in watts) for the entire chassis. The command generates an
Description
error if server throttling is necessary to achieve the power goal based on the value for this setting.
2715–16685 watts
Legal Values
16685 watts
Default
cfgChassisPowerCapF (Read or Write)
Indicates the maximum power consumption limit (in watts) for the entire chassis. Use
Description
cfgChassisPowerCapF when power consumption changes regardless of whether server throttling is
required. This command generates an error if the value for this setting is lower than the minimum power
required for the chassis configuration.
271–16685 watts
Legal Values
16685 watts
Default
cfgChassisPowerCapBTU (Read or Write)
Indicates the maximum power consumption limit (in BTU/hr) for the entire chassis. The command generates
Description
an error if server throttling is necessary to achieve the power goal based on the value for this setting.
9264–56931 BTU/hr
Legal Values
119