Interfaces

Interface
SBus interface
(not with function level "Classic")
Transmission technology
Bus termination
RS-485 diagnostic interface
9.8.1
PROFIBUS interface
PROFIBUS
Function level
PROFIBUS protocol option
Supported baud rates
Bus termination
Maximum line length
9.6 kBaud:
19.2 kBaud:
93.75 kBaud:
187.5 kBaud:
500 kBaud:
1.5 MBaud:
12 MBaud:
Address setting
DP ID number
GSD file name
Bitmap file name
9.8.2
PROFINET interface
PROFINET
Function level
PROFINET protocol option
Supported baud rates
SEW ID number
Unit ID number
Connection technology
Integrated switch
Permitted cable types
Maximum line length
(from switch to switch)
GSD file name
Bitmap file name
Operating Instructions – MOVIFIT
Interface to other SBus-capable SEW units
CAN bus to CAN specification 2.0, parts A and B
ISO 11898-compliant
120 Ê terminating resistor in conjunction with ABOX "MTA...-S02.-...-00" is already
installed and can be activated via the switch.
With all other ABOX versions, you must use an external terminating resistor.
Diagnostic interface, not electrically isolated from MOVIFIT
Classic
PROFIBUS DP/DPV1
9.6 kBaud – 1.5 MBaud / 3-12 MBaud (with automatic detection)
In conjunction with the standard ABOX "MTA...-S02.-...-00", this is already installed and
can be activated via the switch. With all other ABOX versions, you must use an external
terminating resistor.
1,200 m
1,200 m
1,200 m
1,000 m
400 m
200 m
100 m
To extend the length, several segments can be coupled using repeaters. The maximum
expansion/cascading depth can be found in the manuals for the DP master or the repeater
modules.
Addresses 1 to 125 can be set using DIP switches in the connection box.
Classic
600A
(24586
)
hex
dec
Classic
SEW_600A.GSD
Classic
SEW600AN.BMP
SEW600AS.BMP
Classic
PROFINET IO RT
100 MBit/s (full duplex)
010A
hex
2
M12, RJ45 (push-pull) and RJ45 plug connectors (in the ABOX)
Supports autocrossing, autonegotiation
Category 5 and higher, class D in accordance with IEC 11801
100 m in accordance with IEEE 802.3
GSDML-V2.1-SEW-MTX-yyyymmdd.xml
SEW-MTX-Classic.bmp
®
-FC
Technical Data
Interfaces
®
electronics
Technology
Technology
600B
(24587
)
hex
dec
Technology
SEW_600B.GSD
Technology
SEW600BN.BMP
SEW600BS.BMP
Technology
GSDML-V2.1-SEW-MTX-yyyymmdd.xml
SEW-MTX-Technology.bmp
n
kVA
f
i
P
Hz
System
System
077A
(1914
)
hex
dec
System
SEW_077A.GSD
-
9
135