B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 52 of 60)
ADDR
REGISTER NAME
C432
Test Mode Initiate
Clear Commands (Read/Write)
C434
Clear All Relay Records Command
Mandatory (Read Only)
C435
DSP Advanced Diagnostics Active
B
C436
Synchrophasor Feature Active
Mandatory (Read/Write Command)
C437
Relay Reboot Command
C438
Save Volatile Data
Clear Operands (Read/Write Setting)
C450
Clear Fault Reports Operand
C454
Clear Event Records Operand
C456
Clear Oscillography Operand
C458
Clear Data Logger Operand
C45A
Clear Breaker 1 Arcing Current Operand
C45C
Clear Breaker 2 Arcing Current Operand
C466
Clear Channel Status Operand
C46C
Clear Unauthorized Access Operand
C472
Reserved (13 items)
Direct Input/Output Settings (Read/Write Setting)
C500
Direct Input Default States (8 items)
C508
Direct Input Default States (8 items)
C510
Direct Output x 1 Operand (8 items)
C520
Direct Output x 2 Operand (8 items)
Reset (Read/Write Setting)
C750
FlexLogic operand which initiates a reset
Control Pushbuttons (Read/Write Setting) (7 modules)
C760
Control Pushbutton 1 Function
C761
Control Pushbutton 1 Events
C762
...Repeated for Control Pushbutton 2
C764
...Repeated for Control Pushbutton 3
C766
...Repeated for Control Pushbutton 4
C768
...Repeated for Control Pushbutton 5
C76A
...Repeated for Control Pushbutton 6
C76C
...Repeated for Control Pushbutton 7
Force Contact Inputs/Outputs (Read/Write Settings)
C7A0
Force Contact Input x State (96 items)
C800
Force Contact Output x State (64 items)
87L Channel Tests (Read/Write)
C840
Local Loopback Function
C841
Local Loopback Channel
C842
Remote Loopback Function
C843
Remote Loopback Channel
C844
Remote Diagnostics Transmit
Remote Devices (Read/Write Setting) (16 modules)
CB00
Remote Device 1 GSSE/GOOSE Application ID (GOID)
CB21
Remote Device 1 GOOSE Ethernet APPID
CB22
Remote Device 1 GOOSE Dataset
CB23
Remote Device 1 in PMU Scheme
CB24
Reserved
CB25
...Repeated for Device 2
CB4A
...Repeated for Device 3
CB6F
...Repeated for Device 4
B-60
RANGE
0 to 4294967295
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
---
0 to 1
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
0 to 2
0 to 3
0 to 1
1 to 2
0 to 1
1 to 2
0 to 2
---
0 to 16383
0 to 16
0 to 1
0 to 3
L30 Line Current Differential System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F300
---
1
F126
--
1
F126
--
1
F126
---
1
F126
---
1
F126
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
---
F001
---
1
F108
---
1
F108
---
1
F300
---
1
F300
---
1
F300
---
1
F102
---
1
F102
---
1
F144
---
1
F131
---
1
F126
---
1
F001
---
1
F126
---
1
F001
---
1
F223
---
---
F209
"Remote Device
---
1
F001
---
1
F184
---
1
F126
---
1
F626
DEFAULT
1
0 (No)
0 (No)
0 (No)
0 (No)
0 (No)
0
0
0
0
0
0
0
0
0
0 (Off)
0 (Off)
0
0
0
0 (Disabled)
0 (Disabled)
0 (Disabled)
0 (Disabled)
0 (No)
1
0 (No)
1
0 (NO TEST)
1"
0
0 (Fixed)
0 (No)
0 (None)
GE Multilin