GE L30 Instruction Manual page 484

Ur series line current differential system
Hide thumbs Also See for L30:
Table of Contents

Advertisement

A.1 PARAMETER LISTS
Table A–1: FLEXANALOG DATA ITEMS (Sheet 4 of 9)
A
ADDRESS
FLEXANALOG NAME
7202
SRC 2 Pa
7204
SRC 2 Pb
7206
SRC 2 Pc
7208
SRC 2 Q
7210
SRC 2 Qa
7212
SRC 2 Qb
7214
SRC 2 Qc
7216
SRC 2 S
7218
SRC 2 Sa
7220
SRC 2 Sb
7222
SRC 2 Sc
7224
SRC 2 PF
7225
SRC 2 Phase A PF
7226
SRC 2 Phase B PF
7227
SRC 2 Phase C PF
7552
SRC 1 Frequency
7554
SRC 2 Frequency
9024
Prefault Ia Mag [0]
9026
Prefault Ia Ang [0]
9027
Prefault Ib Mag [0]
9029
Prefault Ib Ang [0]
9030
Prefault Ic Mag [0]
9032
Prefault Ic Ang [0]
9033
Prefault Va Mag [0]
9035
Prefault Va Ang [0]
9036
Prefault Vb Mag [0]
9038
Prefault Vb Ang [0]
9039
Prefault Vc Mag [0]
9041
Prefault Vc Ang [0]
9042
Postfault Ia Mag [0]
9044
Postfault Ia Ang [0]
9045
Postfault Ib Mag [0]
9047
Postfault Ib Ang [0]
9048
Postfault Ic Mag [0]
9050
Postfault Ic Ang [0]
9051
Postfault Va Mag [0]
9053
Postfault Va Ang [0]
9054
Postfault Vb Mag [0]
9056
Postfault Vb Ang [0]
9057
Postfault Vc Mag [0]
9059
Postfault Vc Ang [0]
9060
Fault Type [0]
9061
Fault Location [0]
9216
Synchchk 1 Delta V
9218
Synchchk 1 Delta F
9219
Synchchk 1 Delta Phs
9220
Synchchk 2 Delta V
A-4
UNITS
DESCRIPTION
Watts
Source 2 phase A real power
Watts
Source 2 phase B real power
Watts
Source 2 phase C real power
Vars
Source 2 three-phase reactive power
Vars
Source 2 phase A reactive power
Vars
Source 2 phase B reactive power
Vars
Source 2 phase C reactive power
VA
Source 2 three-phase apparent power
VA
Source 2 phase A apparent power
VA
Source 2 phase B apparent power
VA
Source 2 phase C apparent power
---
Source 2 three-phase power factor
---
Source 2 phase A power factor
---
Source 2 phase B power factor
---
Source 2 phase C power factor
Hz
Source 1 frequency
Hz
Source 2 frequency
Amps
Fault 1 pre-fault phase A current magnitude
Degrees
Fault 1 pre-fault phase A current angle
Amps
Fault 1 pre-fault phase B current magnitude
Degrees
Fault 1 pre-fault phase B current angle
Amps
Fault 1 pre-fault phase C current magnitude
Degrees
Fault 1 pre-fault phase C current angle
Volts
Fault 1 pre-fault phase A voltage magnitude
Degrees
Fault 1 pre-fault phase A voltage angle
Volts
Fault 1 pre-fault phase B voltage magnitude
Degrees
Fault 1 pre-fault phase B voltage angle
Volts
Fault 1 pre-fault phase C voltage magnitude
Degrees
Fault 1 pre-fault phase C voltage angle
Amps
Fault 1 post-fault phase A current magnitude
Degrees
Fault 1 post-fault phase A current angle
Amps
Fault 1 post-fault phase B current magnitude
Degrees
Fault 1 post-fault phase B current angle
Amps
Fault 1 post-fault phase C current magnitude
Degrees
Fault 1 post-fault phase C current angle
Volts
Fault 1 post-fault phase A voltage magnitude
Degrees
Fault 1 post-fault phase A voltage angle
Volts
Fault 1 post-fault phase B voltage magnitude
Degrees
Fault 1 post-fault phase B voltage angle
Volts
Fault 1 post-fault phase C voltage magnitude
Degrees
Fault 1 post-fault phase C voltage angle
---
Fault 1 type
---
Fault 1 location
Volts
Synchrocheck 1 delta voltage
Hz
Synchrocheck 1 delta frequency
Degrees
Synchrocheck 1 delta phase
Volts
Synchrocheck 2 delta voltage
L30 Line Current Differential System