GE L30 Instruction Manual page 531

Ur series line current differential system
Hide thumbs Also See for L30:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 33 of 60)
ADDR
REGISTER NAME
778A
Thermal Protection 1 Base Current
778B
Thermal Protection 1 K Factor
778C
Thermal Protection 1 Trip Time Constant
778D
Thermal Protection 1 Reset Time Constant
778E
Thermal Protection 1 Minimum Reset Time
778F
Thermal Protection 1 Reset
7791
Thermal Protection 1 Block
7793
Thermal Protection 1 Target
7794
Thermal Protection 1 Events
7795
Reserved (2 items)
7797
Repeated for Thermal Protection 2
Broken Conductor Detection (Read/Write Settings) (2 modules)
77AA
Broken Conductor 1 Function
77AB
Broken Conductor 1 Source
77AC
Broken Conductor 1 I2/I1 Ratio
77AD
Broken Conductor 1 I1 Minimum
77AE
Broken Conductor 1 I1 Maximum
77AF
Broken Conductor 1 Pickup Delay
77B0
Broken Conductor 1 Block
77B2
Broken Conductor 1 Target
77B3
Broken Conductor 1 Events
77B4
Reserved (2 items)
77B6
...Repeated for Broken Conductor 2
Ohm Inputs (Read/Write Setting) (2 modules)
77F8
Ohm Inputs 1 Function
77F9
Ohm Inputs 1 ID
77FF
Ohm Inputs 1 Reserved (9 items)
7808
...Repeated for Ohm Inputs 2
Phasor Measurement Unit Recorder Config Counter Command (Read/Write Command)
781A
PMU 1 Recorder Clear Config Counter
Phasor Measurement Unit Power Trigger (Read/Write Setting)
7820
PMU 1 Power Trigger Function
7821
PMU 1 Power Trigger Active
7822
PMU 1 Power Trigger Reactive
7823
PMU 1 Power Trigger Apparent
7824
PMU 1 Power Trigger Pickup Time
7825
PMU 1 Power Trigger Dropout Time
7826
PMU 1 Power Trigger Block (3 items)
782C
PMU 1 Power Trigger Target
782D
PMU 1 Power Trigger Events
Phasor Measurement Unit Voltage Trigger (Read/Write Setting)
7858
PMU 1 Voltage Trigger Function
7859
PMU 1 Voltage Trigger Low Voltage
785A
PMU 1 Voltage Trigger High Voltage
785B
PMU 1 Voltage Trigger Pickup Time
785C
PMU 1 Voltage Trigger Dropout Time
785D
PMU 1 Voltage Trigger Block (3 items)
7863
PMU 1 Voltage Trigger Target
7864
PMU 1 Voltage Trigger Events
Phasor Measurement Unit One-shot Command (Read/Write Setting)
788C
PMU One-shot Function
788D
PMU One-shot Sequence Number
788E
PMU One-shot Time
GE Multilin
RANGE
0.2 to 3
1 to 1.2
0 to 1000
0 to 1000
0 to 1000
0 to 4294967295
0 to 4294967295
0 to 2
0 to 1
---
0 to 1
0 to 5
20 to 100
0.05 to 1
0.05 to 5
0 to 65.535
0 to 4294967295
0 to 2
0 to 1
---
0 to 1
---
0 to 65535
0 to 1
0 to 1
0.25 to 3
0.25 to 3
0.25 to 3
0 to 600
0 to 600
0 to 4294967295
0 to 2
0 to 1
0 to 1
0.25 to 1.25
0.75 to 1.75
0 to 600
0 to 600
0 to 4294967295
0 to 2
0 to 1
0 to 1
0 to 99
0 to 235959
L30 Line Current Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
pu
0.01
F001
---
0.05
F001
min.
1
F001
min.
1
F001
min.
1
F001
---
1
F300
---
1
F300
---
1
F109
---
1
F102
---
---
F001
---
1
F102
---
1
F167
%
0.1
F001
pu
0.01
F001
pu
0.01
F001
s
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
---
F001
---
1
F102
---
---
F205
---
1
F001
---
1
F126
---
1
F102
pu
0.001
F001
pu
0.001
F001
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
pu
0.001
F001
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
1
F001
---
1
F050
DEFAULT
80
110
45
45
20
B
0
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
200
10
150
20000
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
"Ohm Ip 1 "
0
0 (No)
0 (Disabled)
1250
1250
1250
10
100
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
800
1200
10
100
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
1
0
B-41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents