I N S T A L L A T I O N P R O C E D U R E S
46
3. Strip the insulation off the wires at 10 ... 11 mm (1).
4. The WAGO connector block has a cage spring wire grip.
Open the grip by pushing down (e.g. with a screwdriver) (2), push the
stripped wire in (3), and release the grip (refer to
5. Check the connection for firm fit and unprotected single wires.
6. Repeat steps (2) to (5) to connect the other wire of the power return (+).
7. Repeat steps (2) to (5) to connect the remaining 2 wires of the negative
voltage power supply (-).
End of instruction
The installation of the FOX power supply is concluded after the installation of
the FOX subrack in the rack with the connection of the subrack to the supply
circuits.
For details, refer to section
Subrack power supply
(on page 60).