Updating CAN Bus TrackID Mapping List
When and where to use:
Perform this procedure to update the Mapping List with the New Unit TrackID.
Procedure:
1 Log on to the Site Controller.
2 To view the mapping list, type can check_mapping.
See example below:
SC> can check_mapping
Units are present:
Device Track ID
DPM 1 JTH0500101
PSU 1 JTH0500200
Units are not present:
DPM 2 JTH0500105
Send Feedback
| September 2014 | 6802800U74-AD
•
Cavity tune timeout: establishes a timeout period between a fine-tuning of the cavities.
All cavities must be fine-tuned at the timeout.
•
Park a cavity: instructs the ATCC to park the specified cavity. This involves adjusting
the cavity resonance to a frequency outside of the Tx band. If RF power is present, the
cavity parks and then re-tunes to the input frequency.
•
VSWR Alarm Threshold: establishes a threshold for enabling a VSWR Alarm. Valid
threshold values are in the range 1.00 to 10.00 where 1.00 means No VSWR.
Recommended values for each MTS configuration are:
-
400 MHz: 3.00
-
260 MHz: 3.00
-
800 MHz: 4.00
Monitoring:
•
Forward power on a digital power monitor: the input power range is from 0 W to 150
W.
•
Reverse power on a digital power monitor: the input power range is from 0 W to 40
W.
•
VSWR from a DPM.
•
DPM temperature.
•
DPM Heartbeat signal.
Alarms:
•
SW is corrupted or unable to initialize.
•
VSWR alarm.
Controls:
•
VSWR Alarm Threshold: establishes a threshold for enabling a VSWR Alarm. Valid
threshold values are in the range 1.00 to 10.00 where 1.00 means No VSWR.
Recommended values for each MTS configuration are:
-
400 MHz: 3.00
-
260 MHz: 3.00
-
800 MHz: 4.00