Siemens RUGGEDCOM RX5000 Installation Manual page 43

Hide thumbs Also See for RUGGEDCOM RX5000:
Table of Contents

Advertisement

RUGGEDCOM RX5000
Installation Guide
Test
IEC 61000-4-16
IEC 61000-4-17
IEC 60255-5
a
Siemens-specified severity levels
IEEE 1613 (C37.90.x) EMI Immunity Type Tests
NOTE
The RX5000 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for
copper ports.
Test
IEEE C37.90.3
IEEE C37.90.2
IEEE C37.90.1
IEEE C37.90.1
Dielectric Strength
EMI and Environmental Type Tests
Description
Mains Frequency Voltage
Ripple on DC Power Supply
Dielectric Strength
HV Impulse
Description
ESD
Radiated RFI
Fast Transient
Oscillatory
HV Impulse
Signal ports
DC Power ports
AC Power ports
Signal ports
30 V Continuous, 300 V for 1 s
DC Power ports
30 V Continuous, 300 V for 1 s
DC Power ports
Signal ports
2 kVAC (Fail-Safe Relay output)
DC Power ports
AC Power ports
Signal ports
5 kV (Fail-Safe Relay output)
DC Power ports
AC Power ports
Enclosure Contact
Enclosure Air
Enclosure ports
Signal ports
DC Power ports
AC Power ports
Earth ground ports
Signal ports
DC Power ports
AC Power ports
Signal ports
DC Power ports
AC Power ports
2 kVAC
Test Levels
2.5 kV common, 1 kV
differential mode @1MHz
2.5 kV common, 1 kV
differential mode @1MHz
10%
1.5 kVDC
2 kVAC
5 kV
5 kV
Test Levels
+/-2 kV, +/-4 kV, +/- 8 kV
+/-4 kV, +/-8 kV, +/-15 kV
35 V/m
+/- 4 kV @ 2.5 kHz
+/- 4 kV
+/- 4 kV
+/- 4 kV
2.5 kV common mode @1 MHz
2.5 kV common, 1 kV
differential mode @ 1 MHz
2.5 kV common, 1 kV
differential mode @ 1 MHz
5 kV (Fail-Safe Relay output)
5 kV
5 kV
Chapter 6
Certification
Severity
Levels
3
3
4
4
3
37