GE t60 Instruction Manual page 560

Ur series transformer protection system
Hide thumbs Also See for t60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 31 of 68)
ADDR
REGISTER NAME
6173
January Average Ambient Temperature
6174
February Average Ambient Temperature
6175
March Average Ambient Temperature
6176
April Average Ambient Temperature
6177
May Average Ambient Temperature
B
6178
June Average Ambient Temperature
6179
July Average Ambient Temperature
617A
August Average Ambient Temperature
617B
September Average Ambient Temperature
617C
October Average Ambient Temperature
617D
November Average Ambient Temperature
617E
December Average Ambient Temperature
Transformer Thermal Inputs (Read/Write Command)
6180
Transformer Loss of Life Clear Command
Transformer Percent Differential (Read/Write Grouped Setting)
61C0
Percent Differential Function
61C1
Percent Differential Pickup
61C2
Percent Differential Slope 1
61C3
Percent Differential Break 1
61C4
Percent Differential Break 2
61C5
Percent Differential Slope 2
61C6
Inrush Inhibit Function
61C7
Inrush Inhibit Level
61C8
Overexcitation Inhibit Function
61C9
Overexcitation Inhibit Level
61CA
Percent Differential Block
61CC
Percent Differential Target
61CD
Percent Differential Events
61CE
Transformer Inrush Inhibit Mode
Transformer Inst Differential (Read/Write Grouped Setting)
61DA
Inst Differential Function
61DB
Inst Differential Pickup
61DC
Inst Differential Block
61DE
Inst Differential Target
61DF
Inst Differential Events
Overfrequency (Read/Write Setting) (4 modules)
6470
Overfrequency 1 Function
6471
Overfrequency 1 Block
6473
Overfrequency 1 Source
6474
Overfrequency 1 Pickup
6475
Overfrequency 1 Pickup Delay
6476
Overfrequency 1 Reset Delay
6477
Overfrequency 1 Target
6478
Overfrequency 1 Events
6479
Reserved (4 items)
647D
...Repeated for Overfrequency 2
648A
...Repeated for Overfrequency 3
6497
...Repeated for Overfrequency 4
Power Swing Detect (Read/Write Grouped Setting)
65C0
Power Swing Detect Function
65C1
Power Swing Detect Source
65C2
Power Swing Detect Mode
65C3
Power Swing Detect Supervision
65C4
Power Swing Detect Forward Reach
B-38
RANGE
-60 to 60
-60 to 60
-60 to 60
-60 to 60
-60 to 60
-60 to 60
-60 to 60
-60 to 60
-60 to 60
-60 to 60
-60 to 60
-60 to 60
0 to 1
0 to 1
0.05 to 1
15 to 100
1 to 2
2 to 3
50 to 100
0 to 2
1 to 40
0 to 1
1 to 40
0 to 4294967295
0 to 2
0 to 1
0 to 2
0 to 1
2 to 30
0 to 4294967295
0 to 2
0 to 1
0 to 1
0 to 4294967295
0 to 5
20 to 65
0 to 65.535
0 to 65.535
0 to 2
0 to 1
0 to 1
0 to 1
0 to 5
0 to 1
0.05 to 30
0.1 to 500
T60 Transformer Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F002
---
1
F002
---
1
F002
---
1
F002
---
1
F002
---
1
F002
---
1
F002
---
1
F002
---
1
F002
---
1
F002
---
1
F002
---
1
F002
---
1
F126
---
1
F102
pu
0.001
F001
%
1
F001
pu
0.001
F001
pu
0.001
F001
%
1
F001
---
1
F168
1 (Adapt. 2nd)
%fo
0.1
F001
---
1
F169
%fo
0.1
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F189
---
1
F102
pu
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
1
F300
---
1
F167
Hz
0.01
F001
s
0.001
F001
s
0.001
F001
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
---
1
F513
pu
0.001
F001
ohms
0.01
F001
DEFAULT
-20
-30
-10
10
20
30
30
30
20
10
10
-10
0 (No)
0 (Disabled)
100
25
2000
8000
100
200
0 (Disabled)
100
0
0 (Self-reset)
0 (Disabled)
0 (Per phase)
0 (Disabled)
8000
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
0
0 (SRC 1)
6050
500
500
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
0 (Two Step)
600
5000
GE Multilin