B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 23 of 54)
ADDR
REGISTER NAME
6203
Percent Differential Break 1
6204
Percent Differential Break 2
6205
Percent Differential Slope 2
6206
Inrush Inhibit Function
6207
Inrush Inhibit Level
B
6208
Overexcitation Inhibit Function
6209
Overexcitation Inhibit Level
620A
Percent Differential Block
620B
Percent Differential Target
620C
Percent Differential Events
620D
Transformer Inrush Inhibit Mode
Transformer Instantaneous Differential (Read/Write Grouped Setting)
6220
Transformer Instantaneous Differential Function
6221
Transformer Instantaneous Differential Pickup
6222
Transformer Instantaneous Differential Block
6223
Transformer Instantaneous Differential Target
6224
Transformer Instantaneous Differential Events
Overfrequency (Read/Write Setting) (4 modules)
64D0
Overfrequency 1 Function
64D1
Overfrequency 1 Block
64D2
Overfrequency 1 Source
64D3
Overfrequency 1 Pickup
64D4
Overfrequency 1 Pickup Delay
64D5
Overfrequency 1 Reset Delay
64D6
Overfrequency 1 Target
64D7
Overfrequency 1 Events
64D8
Reserved (4 items)
64DC
...Repeated for Overfrequency 2
64E8
...Repeated for Overfrequency 3
64F4
...Repeated for Overfrequency 4
Power Swing Detect (Read/Write Grouped Setting)
65C0
Power Swing Detect Function
65C1
Power Swing Detect Source
65C2
Power Swing Detect Mode
65C3
Power Swing Detect Supervision
65C4
Power Swing Detect Forward Reach
65C5
Power Swing Detect Forward RCA
65C6
Power Swing Detect Reverse Reach
65C7
Power Swing Detect Reverse RCA
65C8
Power Swing Detect Outer Limit Angle
65C9
Power Swing Detect Middle Limit Angle
65CA
Power Swing Detect Inner Limit Angle
65CB
Power Swing Detect Delay 1 Pickup
65CC
Power Swing Detect Delay 1 Reset
65CD
Power Swing Detect Delay 2 Pickup
65CE
Power Swing Detect Delay 3 Pickup
65CF
Power Swing Detect Delay 4 Pickup
65D0
Power Swing Detect Seal In Delay
65D1
Power Swing Detect Trip Mode
65D2
Power Swing Detect Block
65D3
Power Swing Detect Target
65D4
Power Swing Detect Event
65D5
Power Swing Detect Shape
65D6
Power Swing Detect Quad Forward Middle
B-30
RANGE
1 to 2
2 to 30
50 to 100
0 to 2
1 to 40
0 to 1
1 to 40
0 to 65535
0 to 2
0 to 1
0 to 2
0 to 1
2 to 30
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 65535
0 to 5
20 to 65
0 to 65.535
0 to 65.535
0 to 2
0 to 1
0 to 1
0 to 1
0 to 5
0 to 1
0.05 to 30
0.1 to 500
40 to 90
0.1 to 500
40 to 90
40 to 140
40 to 140
40 to 140
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 1
0 to 65535
0 to 2
0 to 1
0 to 1
0.1 to 500
T60 Transformer Protection System
UNITS
STEP
FORMAT
pu
0.001
F001
pu
0.001
F001
%
1
F001
---
1
F168
% fo
0.1
F001
---
1
F169
% fo
0.1
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F189
---
1
F102
pu
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
1
F300
---
1
F167
Hz
0.01
F001
s
0.001
F001
s
0.001
F001
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
---
1
F513
pu
0.001
F001
ohms
0.01
F001
degrees
1
F001
ohms
0.01
F001
degrees
1
F001
degrees
1
F001
degrees
1
F001
degrees
1
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
---
1
F514
---
1
F300
---
1
F109
---
1
F102
---
1
F085
ohms
0.01
F001
APPENDIX B
DEFAULT
2000
8000
100
1 (Adapt. 2nd)
200
0 (Disabled)
100
0
0 (Self-reset)
0 (Disabled)
0 (Per phase)
0 (Disabled)
8000
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
0
0 (SRC 1)
6050
500
500
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
0 (Two Step)
600
5000
75
5000
75
120
90
60
30
50
17
9
17
400
0 (Delayed)
0
0 (Self-reset)
0 (Disabled)
0 (Mho Shape)
6000
GE Multilin