Metal-Free Area; Minimum Distance Between Rf340R Readers - Siemens SIMATIC Ident System Manual

Identification rfid systems
Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Readers
5.4 SIMATIC RF340R/RF350R
5.4.1.6

Metal-free area

The RF340R can be flush-mounted in metal. Please allow for a possible reduction in the field
data values.
Figure 5-13
To avoid any impact on the field data, the distance a should be ≥ 20 mm.
5.4.1.7

Minimum distance between RF340R readers

RF340R side by side
D ≥ 200 mm (with 2 readers)
D ≥ 250 mm (with more than 2 readers)
Figure 5-14
138
Metal-free area for RF340R
Minimum distance between RF340R readers
System Manual, 07/2016, C79000-G8976-C345-0x
SIMATIC RF300

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf300

Table of Contents