Readers
5.4 SIMATIC RF340R/RF350R
5.4.1.6
Metal-free area
The RF340R can be flush-mounted in metal. Please allow for a possible reduction in the field
data values.
Figure 5-13
To avoid any impact on the field data, the distance a should be ≥ 20 mm.
5.4.1.7
Minimum distance between RF340R readers
RF340R side by side
D ≥ 200 mm (with 2 readers)
D ≥ 250 mm (with more than 2 readers)
Figure 5-14
138
Metal-free area for RF340R
Minimum distance between RF340R readers
System Manual, 07/2016, C79000-G8976-C345-0x