MODBUS MEMORY MAP
Address
Description
E044
PMU Ic Calibration Angle
E045
PMU Ig Calibration Angle
E046
PMU Seq Volt Shift Angle
E047
PMU Seq Curr Shift Angle
Phasor Measurement Unit Communication (Read/Write Setting)
E048
PMU Com Port Type
E04B
PMU PHS-x (14 items)
E075
PMU PHS-x Name (14 items)
E1C5
PMU A-CH-x (8 items)
E1F5
PMU D-CH-x Name (8 items)
E2B5
PMU D-CH-x (16 items)
E2E5
PMU D-CH-x Name (16 items)
E465
PMU D-CH-x Normal State (16 items)
Phasor Measurement Unit Current Trigger (Read/Write Setting)
E495
PMU Current Trigger Function
E496
PMU Current Trigger Pickup
E497
PMU Current Trigger Pkp Time
E498
PMU Current Trigger Dpo Time
E499
PMU Current Trigger Block
E49D
PMU Current Trigger Events
Phasor Measurement Unit df/dt Trigger (Read/Write Setting)
E49E
PMU df/dt Trigger Function
E49F
PMU df/dt Trigger Raise
E4A0
PMU df/dt Trigger Fall
E4A1
PMU df/dt Trigger Pkp Time
E4A2
PMU df/dt Trigger Dpo Time
E4A3
PMU df/dt Trigger Block
E4A7
PMU df/dt Trigger Events
Phasor Measurement Unit Frequency Trigger (Read/Write Setting)
E4A8
PMU Freq Trigger Function
E4A9
PMU Freq Trigger Low Freq
E4AA
PMU Freq Trigger High Freq
E4AB
PMU Freq Trigger Pkp Time
E4AC
PMU Freq Trigger Dpo Time
E4AD
PMU Freq Trigger Block
E4B1
PMU Freq Trigger Events
Phasor Measurement Unit Reporting Configuration (Read/Write Setting)
E4B2
PMU Network Reporting Function
E4B3
PMU Network Reporting ID Code
E4B4
PMU Network Reporting Rate
E4B5
PMU Network Reporting Style
E4B6
PMU Network Reporting Format
E4B7
PMU Network PDC Control
E4B8
PMU TCP Port Number
E4B9
PMU UDP Port Number
152
Range
Units
-5 to 5
°
-5 to 5
°
-180 to 180
°
-180 to 180
°
0 to 1
---
0 to 14
---
---
---
0 to 4294967295
---
---
---
0 to 65535
---
---
---
0 to 1
---
0 to 1
---
0.1 to 30
pu
0 to 600
s
0 to 600
s
0 to 65535
---
0 to 1
---
0 to 1
---
0.1 to 15
Hz/s
0.1 to 15
Hz/s
0 to 600
s
0 to 600
s
0 to 65535
---
0 to 1
---
0 to 1
---
20 to 70
Hz
20 to 70
Hz
0 to 600
s
0 to 600
s
0 to 65535
---
0 to 1
---
0 to 1
---
1 to 65534
---
0 to 10
---
0 to 1
---
0 to 1
---
0 to 1
---
1 to 65535
---
1 to 65535
---
PLUS
D90
LINE DISTANCE PROTECTION SYSTEM – COMMUNICATIONS GUIDE
CHAPTER 2: MODBUS COMMUNICATION
Step
Format
Default
0.05
F002
0
0.05
F002
0
30
F002
0
30
F002
0
1
F545
1 (None)
1
F543
0 (Off)
---
F203
"GE-UR+PMU-
PHS x"
1
F600
0
---
F203
"AnalogChan
nel x"
1
F300
0
---
F203
"Dig Channel
x"
1
F108
0 (Off)
1
F102
0 (Disabled)
0.001
F001
1800
0.01
F001
10
0.01
F001
100
1
F300
0
1
F102
0 (Disabled)
1
F102
0 (Disabled)
0.01
F001
25
0.01
F001
25
0.01
F001
10
0.01
F001
100
1
F300
0
1
F102
0 (Disabled)
1
F102
0 (Disabled)
0.01
F001
4900
0.01
F001
6100
0.01
F001
10
0.01
F001
100
1
F300
0
1
F102
0 (Disabled)
1
F102
0 (Disabled)
1
F001
1
1
F544
3 (10/sec)
1
F546
0 (Polar)
1
F547
0 (Integer)
1
F102
0 (Disabled)
1
F001
4712
1
F001
4713