GE D90 Plus Communications Manual page 102

Line distance protection system
Hide thumbs Also See for D90 Plus:
Table of Contents

Advertisement

MODBUS MEMORY MAP
Address
Description
72A3
Neg Sequence Directional Overcurrent 1 Forward
ECA
72A4
Neg Seq Directional Overcurrent 1 Forward Limit
Angle
72A5
Neg Sequence Directional Overcurrent 1 Forward
Pickup
72A6
Neg Seq Directional Overcurrent 1 Reverse Limit
Angle
72A7
Neg Sequence Directional Overcurrent 1 Reverse
Pickup
72A9
Negative Sequence Directional Overcurrent 1 Block
72AA
Negative Sequence Directional Overcurrent 1 Events 0 to 1
72AB
Negative Sequence Directional Overcurrent 1 Offset
72AC
Neg Seq Directional Overcurrent 1 Pos Seq Restraint 0 to 0.5
72AD
Neg Seq Directional Overcurrent 1 Reserved (3 items) 0 to 1
72B0
...Repeated for Neg Seq Directional Overcurrent 2
Breaker Arcing Current Settings (Read/Write Setting) (6 Modules)
72C0
Breaker 1 Arcing Amp Function
72C1
Breaker 1 Arcing Amp Source
72C2
Breaker 1 Arcing Amp Limit
72C3
Breaker 1 Arcing Exponent
72C4
Breaker 1 Arcing Rated Interruption
72C5
Breaker 1 Arcing Time Offset
72C6
Breaker 1 Arcing Amp Block
72C7
Breaker 1 Arcing Amp Events
72C8
...Repeated for Breaker 2 Arcing Amp
72D0
...Repeated for Breaker 3 Arcing Amp
72D8
...Repeated for Breaker 4 Arcing Amp
72E0
...Repeated for Breaker 5 Arcing Amp
72E8
...Repeated for Breaker 6 Arcing Amp
IEC 61850 Received Analog Settings (Read/Write) (128 Modules)
7300
IEC 61850 GOOSE Analog 1 Default Value
7302
IEC 61850 GOOSE Analog Input 1 Mode
7303
IEC 61850 GOOSE Analog Input 1 Units
7305
IEC 61850 GOOSE Analog Input 1 Per-Unit Base
7307
...Repeated for IEC 61850 GOOSE Analog Input 2
730E
...Repeated for IEC 61850 GOOSE Analog Input 3
7315
...Repeated for IEC 61850 GOOSE Analog Input 4
731C
...Repeated for IEC 61850 GOOSE Analog Input 5
7323
...Repeated for IEC 61850 GOOSE Analog Input 6
732A
...Repeated for IEC 61850 GOOSE Analog Input 7
7331
...Repeated for IEC 61850 GOOSE Analog Input 8
7338
...Repeated for IEC 61850 GOOSE Analog Input 9
733F
...Repeated for IEC 61850 GOOSE Analog Input 10
7346
...Repeated for IEC 61850 GOOSE Analog Input 11
734D
...Repeated for IEC 61850 GOOSE Analog Input 12
7354
...Repeated for IEC 61850 GOOSE Analog Input 13
735B
...Repeated for IEC 61850 GOOSE Analog Input 14
98
Range
Units
0 to 90
° Lag
40 to 90
degrees 1
0.015 to 30
pu
40 to 90
degrees 1
0.015 to 30
pu
0 to 65535
---
---
0 to 250
ohms
---
---
0 to 1
---
0 to 5
---
0 to 50000
kA2-cyc 1
1 to 5
---
0 to 100
kA
0 to 50
ms
0 to 65535
---
0 to 1
---
–1000000 to 1000000
---
0 to 1
---
---
---
0 to 999999999.999
---
PLUS
D90
LINE DISTANCE PROTECTION SYSTEM – COMMUNICATIONS GUIDE
CHAPTER 2: MODBUS COMMUNICATION
Step
Format
Default
1
F002
75
F001
90
0.005
F001
50
F001
90
0.005
F001
50
1
F300
0
1
F102
0 (Disabled)
0.01
F001
0
0.001
F001
63
1
F001
0
1
F102
0 (Disabled)
1
F167
0 (SRC 1)
F001
1000
0.001
F001
2000
0.1
F001
315
1
F001
0
1
F300
0
1
F102
0 (Disabled)
0.001
F060
1000
1
F491
0 (Default
Value)
---
F207
(none)
0.001
F060
1

Advertisement

Table of Contents
loading

Table of Contents