Technical Data - Bosch SE 220 LSNi Installation Manual

Smartkey arming device
Table of Contents

Advertisement

SE 220 LSNi control unit
Operating voltage
Total current consumption including blocking
element at an input voltage of 9.6 V
- Restore LSN part
- Restore additional
supply
- Bolts being engaged
- Bolts blocked
Total current consumption including blocking
element at an input voltage of 28 V
- Restore LSN part
- Restore additional
supply
- Bolts being engaged
- Bolts blocked
Test input
(pull-up input resistor
on + 5 V)
Environmental condi-
tions
- Environmental class
- Protective system
- Operating tempera-
ture
- Storage temperature
Housing
- Material
- Color
Dimensions (WxHxD)
Weight
VdS approval
(Cl. C) for overall
system
9.6 V...30 V
3.53 mA
41 mA
110 mA for 200 ms
470 mA for 200 ms
3.53 mA
30 mA
65 mA for 200 ms
200 mA for 200 ms
Activate by connect-
ing 0 V. This input is
only intended for test
purposes, i.e. cables
may only be con-
nected
temporarily
for the purpose of
performing a test.
2
IP 30
-5°C...+45°C
-40°C...+85°C
ABS
RAL 9002
135 x 160 x 35 mm
0.25 Kg
G 106064, C
37

Technical Data

Blocking element
Max. distance between
bolt and counterpiece
Bolt break force
Cable to
control unit
Environmental condi-
tions
- Environmental class
- Protective system
- Operating temperature -25°C...+55°C
- Storage temperature
Housing
- Material
- Color
Weight
- Surface mounted mo-
dels
- Recessed mounted
models
Dimensions (WxHxD)
Note on the blocking element: SE 220
LSNi without bolt contact. If all the bolts of
all SE 220 LSNi units in a detection area are
to be activated simultaneously, the values
for "activated bolts" must be added together
when calculating power requirements. Up to
four SE 220 LSNi can be activated within
200 ms due to the time shift caused by the
LSN.
4 mm
approx. 1kN
max. 6 m, 6-pin,
screened,
completely
sealed
3
IP 44
-40°C...+85°C
ABS
RAL 9002
0.45 Kg
0.40 Kg
118 x 28 x 16 mm