Bosch SE 220 LSNi Installation Manual page 18

Smartkey arming device
Table of Contents

Advertisement

Installation Instructions
2.
Key with security card:
Reading in keys via the reader
Keys (maximum 16) can be read in directly via the reader if the 8-digit identification number
is not entered during programming. In the programming program (e.g. WinPara or NzPara),
select for the keys to be read in via the reader (select the parameter "standalone" for SE
220 when using NzPara). The control panel must be programmed before the keys are read
in.
Reading in occurs in two stages. First, the security card is read in, then the keys. Reading in
the security card at the reader replaces the manufacturer's general works code with the indi-
vidual customer code.
Operation sequence:
1. Programming has been concluded with the appropriate settings (see also above).
2.
The plugs with the LSN lines (3.4 and 7.8) must be removed from the control unit.
!
The control panel will display an LSN line malfunction message.
3. Connect the jumper on the control unit's circuit board to bridge B2.
5. Press and hold the key button and hold the first key up to the circle on the center of the
reader at a maximum distance of 2 cm until you hear a short confirmation signal.
6. Repeat step 5 for all the other
keys. The flashing signals of the control
unit's yellow LED and the red LED
on the reader correspond with
the number of keys.
7. Connect the jumper back to B1.
The yellow LED on the control unit and the red LED on the reader go out. This com-
pletes programming the keys.
8. Reconnect the plugs with the LSN lines to the control unit and reset the LSN line mal-
function message on the control panel.
4. Hold the front or the reverse side of the security card parallel
to the reader at a maximum distance of 2 cm until the red LED
lights up.
This completes reading in the security card.
18
1st key
2nd key
3rd key
etc.