NOTE:
and 3. In Disk Manager, logical disks are displayed as 0, 1, and 2. The
default configuration for the data volume can be modified using the Disk
Management utility. Refer to the administration guide for additional
information.
The BIOS supports the following default boot sequence:
1.
CD-RW/DVD-ROM
2.
HDD 0, 1, 2
NOTE:
controller.
3.
PXE (network boot)
Figure 8
Under normal circumstances, the ML110 G1 and DL100 storage server
boots up from the primary OS logical drive. If the system experiences a
drive failure, the Adaptec 2410SA sounds an audible alert to inform the
user of a drive failure.
•
If a single drive failure occurs, it is transparent to the OS.
•
If a second drive fails, the data volume is lost and must be restored
from backup.
36
Server Storage
In Adaptec Storage Manager, logical disks are labeled 1, 2,
This is logical drive 1, 2, and 3 as presented by the SATA RAID
Disk management, partitioning (ML110 G1 and DL100)