Sharp FO-CC500 Service Manual page 22

Accessory cordless handset
Hide thumbs Also See for FO-CC500:
Table of Contents

Advertisement

FO-CC500A
FO-K01A
5.3.9 Headset test mode
1
After going into the mode, cordless handset will check the jack of headset.
2
• If headset are put in the jack, "DETECT HEADSET" will be displayed.
By inputting off key, it goes to stand-by state of Production mode.
1 1 1 1 1
Mode No.
Input key
0
9
5.3.10 Bit rate test mode
1
2
After going into the mode, cordless handset will test the Bit Rate.
By inputting off key, it goes to stand-by state of Production mode.
1 1 1 1 1
Mode No.
Input key
1
0
5.3.11 INTERCOM test mode between cordless handsets (FO-K01 ONLY)
1
After going into the mode, please enter the system ID. (1digit, 0 ~ 9)
NOTE: You have to enter the same number for both partner cordless handsets do this test.
If this test is done at more than 2 places in the communication area, please use the different System ID between each place.
2
This rule is necessary to avoid the jamming.
Please enter the cordless handsets number.
3
NOTE: You have to set the different number for the partner cordless handsets.
4
After above, cordless handset returns to the stand-by mode.
You can call the partner cordless handset by pressing INTERCOM + its cordless handsets number.
The operation after this is equal to the INTERCOM communication specification.
1 1 1 1 1
Mode No.
Input key
2
0
CAUTION: After this test, before packing, you have to do "MEMORY CLEAR".
2 2 2 2 2
End of mode
Input key
OFF
2 2 2 2 2
End of mode
Input key
OFF
2 2 2 2 2
3 3 3 3 3
System ID
Cordless handsets No.
Input key
Input key
0 ~ 9
4 4 4 4 4
End of mode
Input key
OFF
1 ~ 4
2 – 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fo-k01

Table of Contents