3 Press Automatic adjustment.
During automatic adjustment, "in progress" is displayed as the processing status.
The excitation voltage is automatically adjusted inside the IJ printer.
The excitation voltage is gradually increased, and the adjustment is completed
at 60 V ± 5V p-p. (Excitation adjustment is automatically completed within 10 minutes.)
4 When completed, the processing status is displayed to be "Ended".
5 If automatic adjustment fails, the Manual adjustment key is displayed.
Adjust./oper. checkout
<Excitation adjustment>
Excitation voltage value
№
The connection of the EZJ126 board and EZJ125 board is insufficient.
1
The dip switch on the EZJ125 board is incorrectly set.
2
The connection of the coaxial cable connector for excitation (EZJ125 CN5) is
3
insufficient.
Replacement parts are out of order (EZJ126/EZJ125 board, nozzle, head
4
cable).
Proc. status: In progress
Proc. status: Ended
[Stop
]
0752
(0-2047)
Proc. status: Failed
Main causes of automatic adjustment failure
Cause
2-6
Com=0
2015.07.07 12:45
Manual
adjustment
Automatic
adjustment
Back
Manual adjustment