Hitachi IJ RX2 Service Manual page 148

Hide thumbs Also See for IJ RX2:
Table of Contents

Advertisement

4.9.2 Disassembling and washing viscometer
1 Remove the three setscrews from viscometer cover, and then remove the cover.
2 Place the viscometer upside down while fitting wiping paper to the plunger, and then
remove the plunger. (Let all of the ink remaining in viscometer seep out to the wiping
paper.)
3 Make sure that no ink remains in viscometer, and then pull out the cylinder. (If ink remains,
it will dirty the coil.)
4 Put the removed plunger and cylinder in a beaker filled with intensifier, and wash them for
at least 5 minutes using an ultrasonic washer.
Viscometer cover
Three viscometer
cover setscrews
Viscometer cover
Two viscometer IN joint setscrews
Coil
Cylinder
Plunger
Thermistor setscrew
Thermistor
Viscometer case
Squeezing pin
Viscometer IN joint
4-24