5. SYSTEM PARAMETERS
Parameter
Number
P0918
PROFIBUS address
Defines PROFIBUS address or the address of other option modules. There are two
methods of setting the bus address:
1
via the PROFIBUS module DIP switches
2
via a user-entered value
Possible PROFIBUS Settings:
1... 125
0, 126, 127 are not allowed
P0927
Parameters changeable via
Defines how the user is able to change parameters.
Possible Settings:
Setting
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Note
This is a binary parameter
E.g. if you want to set value 15, you will need to set the display to indicate 15 in Binary (with
the separating bars in-between "b - - n n" or if you wanted to set 11 – "b - - r n" etc.
MICROMASTER 420 Operating Instructions
6SE6400-5AA00-0BP0
Parameter Name
RS485 USS
RS232 USS
0
0
0
0
0
0
0
0
0
1
0
1
0
1
0
1
1
0
1
0
1
0
1
0
1
1
1
1
1
1
1
1
BOP
COMMS module
0
0
0
1
1
0
1
1
0
0
0
1
1
0
1
1
0
0
0
1
1
0
1
1
0
0
0
1
1
0
1
1
International English
♦ ♦ ♦ ♦ P0003 User
Min
Access Level
Max
♦ ♦ ♦ ♦ P0004 Setting
[Default]
♦ ♦ ♦ ♦ Changeable
Units
♦ ♦ ♦ ♦ Status
0
2
127
20
[3]
-
0
2
15
20
[15]
-
65