5. SYSTEM PARAMETERS
Parameter
Number
r0056
CO/BO: Status word 1 for V/f
Displays Statusword (V/f) in bit format, which can be used to diagnose inverter status.
Refer to diagram in r0052 for display layout.
Possible values:
Bit 0
Initialization control finished
Bit 1
Motor demagnetizing finished
Bit 2
Pulses enabled
Bit 3
Voltage soft start select
Bit 4
Motor excitation finished
Bit 5
Starting boost active
Bit 6
Acceleration boost active
Bit 7
Frequency is negative
Bit 8
Field weakening active
Bit 9
Volts setpoint limited
Bit A
Slip frequency limited
Bit b
I-max controller active
Bit C
Vdc-max controller active
Bit F
Vdc-min controller active
Note:
Refer to the bitmap diagram on page 51.
P0100
Europe / North America
Determines whether power settings (e.g. nominal rating plate power – P0307) are
expressed in kW or hp. The default settings for the nominal Motor frequency rating (P0310)
and maximum motor frequency (P1082) are also set automatically here, in addition to
reference frequency (P2000).
Possible settings:
0
=
1
=
2
=
Warning:
THE SETTING OF THE kW / HP DIP SWITCH UNDER THE OPERATOR PANEL WILL
OVERWRITE SETTINGS 0 OR 1 AT POWER-UP. Setting 2 will not be overwritten.
Note:
This parameter can only be changed when P0010=1 (Commissioning Mode).
r0206
Rated drive power [kW] or [hp]
Displays the nominal motor power rating, which can be supplied by the inverter.
Note:
The display will be in kW or hp dependent on the setting of P0100
MICROMASTER 420 Operating Instructions
6SE6400-5AA00-0BP0
Parameter Name
Power settings in kW; frequency default 50 Hz (Use DIP Switch 2).
Power settings in hp; frequency default 60 Hz (Use DIP Switch 2)
Power settings in kW; frequency default 60 Hz
International English
0
NO
1
YES
0
NO
1
YES
0
NO
1
YES
0
NO
1
YES
0
NO
1
YES
0
NO
1
YES
0
NO
1
YES
0
NO
1
YES
0
NO
1
YES
0
NO
1
YES
0
NO
1
YES
0
NO
1
YES
0
NO
1
YES
0
NO
1
YES
♦ ♦ ♦ ♦ P0003 User
Min
Access Level
Max
♦ ♦ ♦ ♦ P0004 Setting
[Default]
♦ ♦ ♦ ♦ Changeable
Units
♦ ♦ ♦ ♦ Status
-
2
-
13
[-]
-
0
1
2
1
[0]
'
'
-
-
2
-
2
[-]
-
53