Dispensing liquid cleaning agent via DOS 1

Setting the dosage concentration

The dosage concentration must be set exclusively for liquid cleaning agent.
Set it according to the manufacturer's recommendations or the official
standards required.
The dosage concentration must not be altered even if powder cleaning agent
is dispensed via the dispenser in the door.
Step
^ Press 0 until E02 appears.
^ Turn the programme selector to
"Inorganica".
without DOS Module connected:
with DOS Module connected:
^ Press ß as many times as necessary
or hold pressed in until the required
value appears in the display, e.g. 0.50.
Dosage concentration set:

Venting the dispensing system

The dispensing system must be vented:
– when the dosage concentration is set for the first time,
– if the liquid cleaning agent container runs out and is not refilled in time.
Step
^ Press 0 until E02 appears.
^ Turn the programme selector to
"Custom".
^ Press ß.
^ Exit from programming mode.
Then start the "Rinse" programme.
Programmable functions
Display / Result
E02
10 = 10 sec dosage duration
1.00 = 1.0 % dosage concentration
0.50
The dosage duration/concentration
level has now been set.
Display / Result
E02
d§1
The dispensing system will be vented
automatically. 0 will appear in the display
when the venting process has finished.
Any agents which are in the wash cabinet
after the venting process will be diluted
before being drained away.