GE Multilin G650 Manual page 617

Generator protection & control system
Hide thumbs Also See for Multilin G650:
Table of Contents

Advertisement

F.1 FACTORY DEFAULT SETTINGS
SETPOINT > PROTECTION ELEMENTS > GROUND CURRENT > GROUND IOC
GROUND IOC 1> GROUND IOC 2 > GROUND IOC 3
SETTING DESCRIPTION
Function permission
Input type
Pickup level
Trip time
Reset time
Snapshot event generation
SETPOINT > PROTECTION ELEMENTS > GROUND CURRENT > GROUND DIRECTIONAL >
GROUND DIRECTIONAL 1> GROUND DIRECTIONAL 2 > GROUND DIRECTIONAL 3
SETTING DESCRIPTION
Function permission
Maximum Torque Angle
Operation Direction
Polarization type
Block logic type
Polarization voltage threshold
Snapshot event generation
SETPOINT > PROTECTION ELEMENTS > GROUND CURRENT > RESTRICTED GROUND FAULT (ENHANCED MODELS ONLY) >
RESTRICTED GND FAULT 1> RESTRICTED GND FAULT 2 > RESTRICTED GND FAULT 3
SETTING DESCRIPTION
Function permission
F
Pickup level
Function slope
Time delay
Snapshot event generation
SETPOINT > PROTECTION ELEMENTS > SENSITIVE GROUND CURRENT > SENSITIVE GROUND TOC (ENHANCED MODELS
ONLY)
SENSITIVE GROUND TOC 1> SENSITIVE GROUND TOC 2 > SENSITIVE GROUND TOC 3
SETTING DESCRIPTION
Function permission
Input type
Pickup level
Curve shape
Time Dial
Reset type
Snapshot Event generation
F-10
NAME
DEFAULT VALUE
Function
DISABLED
Input
PHASOR(DFT)
Pickup Level
30.00
Trip Delay
0.00
Reset Delay
0.00
Snapshot Events
ENABLED
NAME
DEFAULT VALUE
Function
DISABLED
MTA
-45
Direction
FORWARD
Polarization
VO
Block Logic
PERMISSION
Pol V Threshold
10
Snapshot Events
ENABLED
NAME
DEFAULT VALUE
Function
DISABLED
Ground Fault Pickup
10.00
Ground Fault Slope
10.00
Ground Fault Delay
0.10
Events
ENABLED
NAME
DEFAULT VALUE
Function
DISABLED
Input
PHASOR(DFT)
Pickup Level
0.050
Curve
IEEE Ext Inv
TD Multiplier
1.00
Reset
INSTANTANEOUS
Snapshot Events
ENABLED
G650 Generator Protection & Control System
STEP
RANGE
N/A
[DISABLED – ENABLED]
N/A
[PHASOR – RMS]
0.01 A
[0.05 : 160.00]
0.01 s
[0.00 : 900.00]
0.01 s
[0.00 : 900.00]
N/A
[DISABLED – ENABLED]
STEP
RANGE
N/A
[DISABLED – ENABLED]
1 Deg
[-90 : +90]
N/A
[FORWARD – REVERSE]
[V
– I
– V
+I
– V
N/A
0
P
0
P
N/A
[BLOCK – PERMISSION]
1 V
[0 : 500]
N/A
[DISABLED – ENABLED]
STEP
RANGE
N/A
[DISABLED – ENABLED]
0.01 CT
0.02 – 20.00
0.01%
0.00 – 100.00
0.01 s
0.00 – 600.00
N/A
[DISABLED – ENABLED]
STEP
RANGE
N/A
[DISABLED – ENABLED]
N/A
[PHASOR – RMS]
0.001 A
[0.005 : 16.000]
N/A
[See list of curves]
0.01 s
[0.00 : 900.00]
[INSTANTANEOUS –
N/A
LINEAR]
N/A
[DISABLED – ENABLED]
APPENDIX F
USER
VALUE
USER
VALUE
*I
]
0
P
USER
VALUE
USER
VALUE
GEK-113285A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents