Siemens HiPath 5000 Service Manual page 1155

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

Sample calculation for a HiPath 3550
1.
Determine overall secondary power requirement
power requirements of the boards/
components used =
+
power requirement of connected work-
point clients, key modules and adapt-
ers =
=
overall secondary power requirement
=
2.
Identifying primary power requirement
overall secondary power requirement
=
+
UPSC-D requirement =
Allow for the degree of efficiency of the
power supply unit:
The primary power requirement of HiPath 3550 with the expansion mentioned
amounts to approximately 103.7 W.
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
Identifying System Power Requirements
Identifying the Primary System Power Requirement
7.50 W
1 x CBCC
12.80 W
1 x HXGS3 (including ventilator
kit)
0.90 W
1 x TS2
2.40 W
3 x SLU8
2.60 W
1 x 8SLA
5.00 W
1 x SLC16N
24.00 W
12 x BS3/1
0.56 W
1 x optiset E memory
4.32 W
6 x optiPoint 500 advance
0.85 W
1 x optiset E advance confer-
ence/conference
8.40 W
12 x optiPoint 500 basic
2.40 W
8 x optiPoint 500 entry
0.00 W
2 x Hicom Attendant BLF
0.00 W
2 x optiPoint BLF
0.40 W
8 x optiPoint key module
0.50 W
2 x optiPoint acoustic adapter
1.80 W
6 x analog workpoint clients
74.43 W
74.43 W
12.00 W
86.43 W
x 1.2 = 103.7 W
power_calc.fm
D-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 3000Hipath 3800

Table of Contents